Plan Review Notes
Plan Review Notes For Permit 02040691
Permit Number 02040691
Review Stop P
Sequence Number 1
Notes
Date Text
2002-05-07 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT #1 PLEASE GIVE DIMENSIONS FOR
 EXISTING RESTROOMS.
 2) SHT #1 DOOR SWING SHALL NOT OPEN INTO
 THE CLEAR FLOOR SPACE OF HDCP LAV. FBC-
 2001 SEC 4.17.3
 3) SHT #1 SI SINK SHALL COMPLY WITH SEC
 11-424. GIVE DETAILS FOR ALL SUBSECTIONS
 4) SHTS #1 & #3 JANITOR SINK REFERED TO
 ON SANT. RISER DIAGRAM NOT SHOWN ON DEMO
 SHT OR FLOOR PLAN?? PLEASE SHOW JANITOR
 SINK OF FLOOR PLAN. (TABLE 403.1 - FBC-
 2001 PLUMBING REQUIRES 1 SERVICE SINK).
 5) SHT #3 PLUMBING NOTE #7 - AIR CHAMB-
 ERS ARE NOT APPROVED. WATER HAMMER ARRES
 TORS ARE REQUIRED ON ALL QUICK CLOSING
 VALVES ONLY. (WASH MACHINES, ICE MAKERS,
 DISHWASHERS ECT.) IF USED THEY SHALL BE
 LOCATED NEAR FIXTURE, IN AN "EFFECTIVE
 RANGE", NOT AT TOP OF DROP.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377