Date |
Text |
2004-06-01 00:00:00 | ****CORRECTIONS**** |
| ARCHITECTURAL REVISION, VARIOUS |
| SHEETS, DATED 4/12/04 |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| [email protected] |
| |
| 1.)SHEET A1.04 SHOWS TWO SLOPES |
| GREATER THAN 1:50, NOT COMPLIANT WITH |
| FBC11-4.6.3. (SEE REVIEW SET) |
| |
| 2.)SHEET A2.02 IS NOT SIGNED AND |
| SEALED ON REVIEW SET. |
| |
| 3.)SHEET A1.06, AT 17'5" ELEVATION, |
| STAIR 3, WHAT IS THE PURPOSE OF THE |
| DOOR IN THE MIDDLE OF THE STAIR LANDING? |
| |
| 4.)THE REVISIONS AFFECT MEPS.SUBMIT |
| THE REVISIONS AS NECESSARY. |
| |
| 5.)SHEETS 5.08 AND 5.09, WHERE IS |
| THE DETAIL FOR THE METAL STUD WALLS? |
| THE RECENT STRUCTURAL REVISION |
| SUBMITTED SHOWS THESE WALLS AS A TYPE |
| W3, CONCRETE WALL.TRANSMITTAL LETTER |
| INDICATES THE WALLS AS "SHOWN WITHOUT |
| CONCRETE - TO BE METAL STUD |
| CONSTRUCTION."PLEASE CLARIFY. |
| |
| 6.) A3.09 REFERS TO FOAM COLUMN AND |
| PANEL.ARCHITECTURAL TRIM ON BUILDINGS |
| LOCATED IN THE FIRE DISTRICT SHALL BE |
| CONSTRUCTED OF APPROVED NONCOMBUSTIBLE |
| MATERIALS OR FIRE RETARDANT TREATED |
| WOOD, F102.2.7 CITY OF WEST PALM BEACH |
| AMENDMENTS TO THE FBC, FBC1404. |
| |
| 7.)PROVIDE CALCULATIONS FOR STAIR |
| #5, THE NEW EGRESS STAIR, TO SHOW |
| COMPLIANCE WITH FBC412.11(5). |
| |
| 8.)DOORS IN THE STAIRWAY ENCLOSURES |
| ARE TO COMPLY WITH FBC705.1.3.4. |
| |
| 9.)PROVIDE A DETAIL FOR TYPE I |
| REFERRED TO ON SHEET 5.12 (2 HR SHAFT). |
| |
| 10.) SHEET 6.04, PROVIDE A CONSTRUCTION |
| DETAIL, INCLUDING METHOD OF ATTACHMENT |
| TO THE BUILDING, FASTENING CONNECTION |
| DETAILS. |
| |
| 11.) TRASH CHUTES SHALL COMPLY WITH |
| NFPA82 3-2.4.3.1, THE SIZE OF THE |
| SERVICE OPENING ROOM OR COMPARTMENT |
| SHALL NOT BE LESS THAN THAT REQUIRED TO |
| MAINTAIN A MINIMUM OF 6" CLEARANCE |
| BETWEEN THE OPEN LOADING DOOR AND THE |
| CLOSED SERVICE OPENING ROOM DOOR. |