Plan Review Notes For Permit 02031450 |
Permit Number |
02031450 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2002-04-02 00:00:00 | BUILDING PLAN REVIEW | | PERMIT # 02031450 | | 9132 BAY HARBOUR CIR | | CONT : SCREEN BUILDERS | | TEL 1:800 972-7242 X 325 | | | | PLANS HAVE DISCREPANCY, FOOTER DETAILS | | SHEET ENTITLED FOOTING LAYOUT INDICATES | | A 8"X8" FOOTING PLUS PAVERS.DETAIL SHEET | | INDICATES A "CHECKED MONOLITHIC FOOTING | | DETAIL WITH A 10"X 8" MONO FOOTING, | | ANOTHER DETAIL "CHECKED" INDICATES | | TAPCONS INTO A CONCRETE SLAB NOT THE | | PAVER DETAIL? "CHECK THE APPROIATE | | APPLICATIONS! | | BUILDING PLAN REVIEW | | JIM WITMER |
|