2002-05-13 00:00:00******************DENIED****************
  
 MECHANICAL PERMIT 02031335
  
 SEER ON ENERGY CALCS OKAY.
  
 OTHER COMMENTS NOT ADDRESSED FROM PREVIO
 US REVIEW.
  
 1. O.A. CALCS
 2. DRYER CFM NOT PROVIDED
 3. DRYER LENGTHS IN EXCESS OF CODE MIN.
 25'OR PROVIDE MANUFACTURER SPECS
 INDICATING SPECIFIC ALLOWABLE LENGTH.
 4. SECONDARY DRAIN CONSPICUOUS POINT
 SHALL NOT BE BEHIND AHU UNIT DOOR. IF
 NO SUITABLE CONSPICUOUS LOCATION IS
 AVAILABLE, A PAN WITH A FLOAT SWITCH
 PER 307.2.4 IS ACCEPTABLE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.