2002-03-26 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT # 02021973 |
| 3101 WADDELL AV |
| |
| SBC= 1997 STANDARD BUILDING CODE |
| |
| 1)- THIS PROJECT REQUIURES A RESIDENT IN |
| SPECTOR, 3 SETS OF PLAN REQUIRED FOR |
| EVERY TOWNHOUSE ISSUED. |
| |
| 2)- SBC 1606.2.6.2 COMPONENTS & CLADDING |
| MISSING THE NORANDEX REPORTS FOR WINDOWS |
| AND DOORS SITE SPECIFIC, ADDRESS TO BE |
| ON EACH SIGNED & SEALED COPY. |
| |
| 3)-SCREEN ENCLOSURES ARE TO BE A SEPER- |
| ATE PERMIT WITH ASSOCIATED FEES. |
| |
| 4)- SHEET 12/ 15 THE 5050 SH WINDOW IN |
| THE BREAKFAST AREA IS TO LARGE TABLE 600 |
| |
| 5)- SHEET 5,6 & 10 TRUSSES REVIEWED |
| UNDER 02010168, FG-5 A5 INDICATES A 3 |
| POINT BEARING GIRDER TRUSS, TTRUSS ENG. |
| INDICATES A 5 POINT BEARING, MISSING |
| BEARING POINTS 13,14. |
| |
| 6)- SG-1 TRUSS ENG POINT # 5 INDICATES |
| 2060 LBS. UPLIFT WHERE AS SH A5 NOTE A-3 |
| INDICATES 1370 OR 1890 LBS SHORT RESTRAI |
| NT OR UPLIFT VALUE. |
| |
| 7)- TRUSS ENG H-4 TRUSS ENG POINT #1 |
| INDICATES 3203 LBS UPLIFT, POINT 11 INDI |
| CATES 3174, ARCH A-6 DETAIL 4/10 IS A |
| WALL SECTION TO A FLOOR GIRDER TRUSS |
| CONNECTION MISSING INFO FOR THE ROOF |
| TRUSS 2ND STORY WALL CONNECTION? |
| |
| 8)- TRUSS ENG H-5 H-8 & T-1 INDICATE A |
| 3" BEARING END (BUCKET) ARCH SHEET A6 |
| INDICATES A (WA-5) NOT IN SCHEDULE? |
| |
| 9)- WHERE MULTIPLE STRAPS ARE TO BE USED |
| IN CMU OR CONCRETE A DERATING SHALL BE |
| REQUIRED WHEN USED CLOSER THAN 8". |
| USP SHALL CALCULATE THE AMOUNT OF DERAT- |
| ING REQUIRED. |
| |
| 10)- SHEET A-6 DETAIL 2 INDICATES A |
| STRAP TO BE WELDED TO A MANUFACTURED |
| BUCKET. SHALL REQUIRE THE MANUFACTURES |
| APPROVAL & FIELD WELDING REQUIRES CERTI- |
| FICATION OF THE WELDER. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| (561)659-8096 X8412 |