Date |
Text |
2002-04-11 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT NUMBER 02021880/ |
| 02021869 |
| 8260/ 8270 MANJACK CAY |
| CONT: TAZ CONSTRUCTION |
| TEL: (954)340-1744 |
| |
| SBC= 1997 STANDARD BUILDING CODE |
| |
| 1)- SBC 1606.2.6.2 COMPONENTS & CLADDING |
| PRODUCT APPROVALS ARE REQUIRED FOR |
| GLAZED OPENINGS, BROWARD COUNTY FORMS |
| REQUIRE SITE SPECIFIC ENGINEERING AND |
| THE DESIGN PROFESSIONAL OF RECORD SHALL |
| AFFIX HIS SEAL TO THE AFFIDAVIT ATTEST- |
| ING THAT THIS PRODUCT MEETS THE WIND |
| LOADING OF THE 1997 STANDARD BUILDING |
| CODE. |
| IF THE DESIGN PROFESIONAL IS RELUC |
| TENT TO SIGN & SEAL THE BROWARD COUNTY |
| FORM HE MAY ATTACH HIS AFFIDAVIT TO THE |
| BROWARD FORM ATTESTING THIS PRODUCT DOES |
| MEET THE WIND REQUIREMENTS OF THE 1997 |
| STANDARD BUILDING CODE, AGAIN HE SHALL |
| SIGN & SEAL THE AFFADAVIT. FL .STATE |
| STATUTE 61G1-16.001 PLANS, SPECS, RE- |
| PORTS PREPARED BY OR ISSUED BY THE DE- |
| SIGN PROFESSIONAL AND FILED FOR PUBLIC |
| RECORD SHALL BEAR THE DESIGN PROFESSION- |
| ALS SIGNATURE AND HAVE HIS SEAL ATTACHED |
| THIS ISSUE HAS TO DEAL WITH: |
| A) KINCO LIMITED ALUMINUM SLIDING |
| GLASS DOORS |
| B) KINCO- ALUMINUM SINGLE HUNG |
| WINDOWS |
| 2)- MISSING THE REPORT FOR THE MULLION, |
| DRAWING # M99-03 |
| 3)- SBC 1606.2.6.2 COMPONENTS & CLADDING |
| 1606.4.1/1707.4.1 CITY STANDARD FOR |
| FOR HURRICANE MISSLE IMPACT PROTECTION |
| SEE ITEM #15, SITE SPECIFIC CONDITIONS. |
| 1"X4" MULLION REPORT ISSUED BY P.E. |
| K.VENKATESAN, THIS REPORT TO BE SITE |
| SPECIFIC, ALSO SHALL REQUIRE ENGINEERS |
| SEAL WHICH IT HAS, THE DESIGNER OF RE- |
| CORD WHICH IT DOESN'T NOR IS IT SITE |
| SPECIFIC! |
| 4)- ANCHOR LEGEND & DETAILS: SEMCO & |
| HUGHES ARE NOT IN BUSINESS ANY MORE, |
| CORRECT TO NEW PROVIDER. |
| 5)- ANCHOR LEGEND, (2) INDICATES THE USE |
| OF TWO TAPR216 STRAPS, WHEN USED CLOSER |
| THAN 8" A DERATING FACTOR IS TO BE USED. |
| 6)- ANCHOR LEGEND, (4) INDICATES THE USE |
| OF TWO TAPR222 WITH A UPLIFT LOAD OF |
| 3900 LBS, NOT ONLY WAS THERE NO DERATING |
| AN ADDTIONAL 1000 LBS WAS ADDED TO THE |
| ALLOWABLE LOADS. |
| 1 TAPR 222 = @160% =1485 LBS UPLIFT. |
| 7)- CONTRACTOR TO SUBMIT PLANS TO COUNTY |
| FOR IMPACT FEE ASSESSMENT BEFORE PERMIT |
| ISSUANCE. |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| (561)659-8096X8412 |