2002-03-07 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) THE SUBMITTED NOTICE OF COMMENCEMENT
 IS NOT VALID UNTIL RECORDED BY THE
 CLERK OF THE CIRCUIT COURT.
  
 3) FBC 424.2.17.1SHEET A1.00, SITE
 DEMOLITION PLAN.THE POOL FENCING IS
 SHOWN AS BEING REMOVED.THE SWIMMING
 POOL SHALL BE PROVIDED WITH A BARRIER.
 THIS IS A REQUIREMENT OF FLORIDA
 BUILDING CODE 2001, SECTION 424
 (SWMMING POOLS AND BATHING PLACES). THIS
 SECTION WAS SPECIFICALLY ADOPTED,
 STATEWIDE, ON JANUARY 2001.
  
 4) SBC 1005.4SHEET A3.10, WINDOW
 SCHEDULE, NOTE 9.THE NOTE STATES THAT
 THE REQUIRED NET CLEAR EGRESS WINDOW
 OPENING IS 20"WIDE X 22" HIGH.THIS
 SHOULD READ 20"WIDE X 24"HIGH.THE SILL
 HEIGHT SHALL BE NO MORE THAN 44" ABOVE
 THE FLOOR.
  
 5) SBC* 104.2SHOW WINDOW W101 ON THE
 EAST ELEVATION.AMEND THE SECOND FLOOR
 PLAN TO SHOW THE SECOND FLOOR WINDOW
 INDICATED ON THE NORTH ELEVATION.
  
 6) SBC* 104.2 DOOR SCHEDULE, SHEET A3.10
 THE MASTER BEDROOM DOOR REFERENCES D204
 AND D205 DO NOT CORRELATE WITH THE
 DETAILS GIVEN IN THE DOOR SCHEDULE.THE
 REFERENCES SHALL BE CORRECTED.
  
 7) SBC* 1606.4.2PRODUCT APPROVALS.
 SUBMIT A PRODUCT APPROVAL NOTICE OF
 ACCEPTANCE FOR EACH OF THE NEW WINDOWS
 AND EXTERNAL DOORS (INCLUDING DOOR D108)
  
 8) SBC* 1606.4.2PRODUCT APPROVAL. WITH
 REFERENCE TO THE FRANK L BENNARDO, P.E.
 LETTERS DATED FEBRUARY 4 AND 15, 2002,
 PRODUCT APPROVAL SUBMITTAL FORMS (BLANK
 COPIES ATTACHED TO THE COMMENTS) SHALL
 BE COMPLETED BY THE CERTIFYING ENGINEER
 AND THEN SIGNED BY THE ENGINEER OF
 RECORD FOR THE PROJECT.ALSO, THE
 EXISTING AND PROPOSED LOCATIONS OF THE
 'EXISTING SOLID CORE WOOD OUTSWING
 SINGLE ENTRY DOORS' ARE NOT STATED ON
 THE PLANS.AMEND THE PLANS TO CLARIFY.
  
 9) SBC104.1.1THE FRANK L BENNARDO, P.E
 LETTER DATED FEBRUARY 4, 2002 REQUIRES
 THE INSTALLATION OF "AN APPROVED IMPACT
 PROTECTION SYSTEM".A SEPARATE SHUTTER
 PERMIT APPLICATION WILL BE REQUIRED.
  
 10) SBC* 1606.4.2SBCCI EVALUATION OF
 THE GARAGE DOORS.THE SUBMITTED
 INSTALLATION DRAWING IS NOT LEGIBLE AS
 IT HAS BEEN REPEATEDLY COPIED AND/OR
 FAXED.SUBMIT A LEGIBLE COPY.
  
 11) SBC 2308THE PLYWOOD SHEATHING IN
 THE SECOND FLOOR EXTERIOR WALL SHALL BE
 MIN. 5/8" THICK (SBC TABLE 2308.2.2B).
 ALSO, PROVIDE DETAILS OF THE MEANS OF
 ATTACHMENT FOR THIS WALL WHERE IT ABUTTS
 THE WALL OF THE EXISTING BUILDING.
  
 12) SBC* 104.1.1 ROOF COVERING DETAILS
 HAVE NOT BEEN SUBMITTED.A SEPARATE
 ROOFING PERMIT APPLICATION WILL BE
 REQUIRED.
  
 13) SBC 2309.2SUBMIT A ROOF TRUSS
 LAYOUT AND DESIGN DATA.
  
 14) SBC* 2304.1.2THE TERMITE TREATMENT
 OF SOIL UNDER AND AROUND THE FOOTINGS
 AND SLABS ON-GRADE SHALL BE PERFORMED IN
 ACCORDANCE WITH THE REQUIREMENTS OF
 CHAPTERS 482 AND 487 FLORIDA STATUTES,
 AND SECTION 5E-14.106 FLORIDA
 ADMINISTRATIVE CODE.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499