Date |
Text |
2002-02-26 00:00:00 | DENIED |
| REFERENCE: SPC-94-FACBC-97 |
| |
| 1) PLANS SHALL BE ROUTED TO THE PALM |
| BEACH COUNTY HEALTH UNIT, DIVISION OF |
| ENVIRONMENTAL HEALTH. 901 EVERNIA STREET |
| WPB FLA 33401. THIS SHALL BE DONE BEFORE |
| RESUBMITTING FOR PLAN REVIEW. |
| 2) PLEASE SUBMIT CALCULATIONS FOR MINI- |
| MUM FACILITIES. USE SPC TABLE 407 AND |
| SEC 407.1.3 |
| 3) SHTS P-1/P-2 GREASE REISE DIA. DOES |
| NOT REFLECT FLOOR PLAN. FLOOR PLAN SHOWS |
| THREE FLOOR DRAINS TAKEN OFF FROM BLDG |
| DRAIN. RISER DIAGRAM SHOWS ONE TAKEN OFF |
| FROM BLDG DRAIN, AND ONE TAKEN OFF FROM |
| BRANCH LINE AFTER 3 COMPARTMENT SINK. |
| 4) SHTS P-1/P-2 FLOOR SINK REQUIRED FOR |
| INDIRECT WASTE FROM ICE MAKER. FLOOR |
| DRAIN NOT APPROVED. SPC SEC 804.5 |
| 5) SHTS P-1/P-2 JANITOR MOP SINK TO BE |
| ON GREASE WASTE SYSTEM NOT SANITARY. |
| 6) SHTS P-1/P-2 ANY SINKS IN FOOD PREP |
| AREA SHALL BE INDIRECT WASTE TO FLOOR |
| SINK. SPC SEC 804.1 |
| 7) SHTS P-1/P-2 SANITARY RISER DIAGRAM |
| DOES NOT REFLECT FLOOR PLAN. |
| A) SINK BEHIND HDCP LAV IN WOMENS REST |
| ROOM ON RISER DIAGRAM NOT SHOWN ON FLOOR |
| PLAN. |
| B) DRINKING FOUNTAINS BY MENS AND WOMEN |
| REST ROOMS ON FLOOR PLAN NOT SHOWN ON |
| RISER DIAG. |
| C) ARTS & CRAFTS TAKEN OFF BEFORE MENS |
| ROOM ON FLOOR PLAN BUT NOT ON RISER DIA. |
| D) CLEAN OUT AT CHANGE OF DIRECTION TO |
| MENS ROOM MISSING ON RISER DIA. |
| E) OFFICE BATH ROOM TAKEN OFF AFTER |
| DRAIN LINE TURNS TO MENS ROOM NOT RE- |
| FLECTED ON RISER DIA. |
| F) FLOOR DRAIN BETWEEN URNAL AND W/C IN |
| MENS ROOM SHOWN ON FLOOR PLAN NOT SHOWN |
| ON RISER DIAGRAM. |
| 8) SHT ME-1 PLEASE SUBMIT STORM RISER |
| DIAGRAM. |
| |
| REVIEW BY KEN STEVENS |
| (561) 659-8096 EXT 8377 |