2002-04-30 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT # 02011628 |
| 1609 S DIXIE HWY |
| CONT: MIKE MOORE |
| TEL: 775-3447 |
| |
| SBC= 1997 STANDARD BUILDING CODE |
| |
| 1)- PROVIDE (2) CURRENT AND COMPLETE |
| COPIES OF SBCCI OR METRO-DADE PRODUCT |
| APPROVALS FOR: HURRICANE STOREFRONT |
| SYSTEM, ARCHITECT NOTE, STOREFRONT SUB- |
| CONTRACTOR SHALL PROVIDE WIND LOAD CALCU |
| LATIONS FROM A REGISTERED ENGINEER, TO |
| ESTABLISH SIZES AND ANCHORING? |
| IS THIS TO BE A SEPERATE PERMIT, OR |
| IS THIS INFORMATION TO BE INCLUDED |
| UNDER THIS PERMIT? |
| |
| 2)- ROVIDE 2 CURRENT COPIES OF SIGNED & |
| SEALED SURVEYS WITH PROPOSED IMPROVEMENT |
| TO BE COMPLETED.THEFRONT AND REAR |
| DOORS INDICATE THEY ARE SWINGING OVER |
| THE PROPERTY LINE. |
| |
| 3)- 3203.1 DOORS SHALL NOT OPEN OR |
| PROJECT UPON PUBLIC PROPERTY. |
| |
| 4)- TABLE 704.1 OCCUPANCY SEPERATION |
| REQUIREMENTS;MERCANTILE/ STORAGE |
| LOW HAZARD 2HRS. INDICATE THE CEILING / |
| 2ND FL. ASSEMBLY NUMBER? |
| |
| 5)- 106.4.3 POSTING OF FLOOR LOADS, IT |
| SHALL BE THE OWNER, AGENT TO EMPLOY A |
| COMPUTANT DESIGN PROFESSIONAL TO COMPUTE |
| THE SAFE ALLOWABLE FLOOR LOADS. ALL |
| SUCH COMPUTATIONSSHALL BE ACCOMPANIED |
| BY AN AFFIDAVITFROM THE DESIGN PROFES- |
| SIONAL STATING THE SAFE FLOOR LOAD. THE |
| COMPUTATION & AFFIDAVIT SHALL BE ON FILE |
| AS A PERMANENT RECORD OF THE BUILDING |
| DEPARTMENT. |
| |
| ANY QUESTIONS PLEASE CALL, |
| JIM WITMER |
| BUILDING PLAN REVIEW |
| DEPARTMENT OF CONSTRUCTION SERVICES |
| CITY OF WEST PALM BEACH |
| (561) 659-8096 EXT. 8412 |