Plan Review Notes For Permit 02011628 |
Permit Number |
02011628 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2002-04-19 00:00:00 | DENIED | | REFERENCE: SPC-94-FACBC-97 | | | | 1) FROM PREVIOUS REVIEW - SHT A-1 EXIST- | | ING TOILET ROOM AT NORTH WEST CORNER OF | | STORAGE AREA. IS THIS TOILET ROOM HDCP | | ACCESSIBLE, AND CAN IT BE ACCESSED FROM | | THE STORAGE AREA? | | 2) TO CALCULATE MINIMUM FACILITIES FOR | | STORAGE AREAS,(FIRST & SECOND FLOOR), WE | | NEED TO KNOW THE NUMBER OF PEOPLE WORK- | | ING PER SHIFT IN STORAGE AREAS. | | 3) SHT ME-2 WATER HAMMER ARRESTORS ARE | | LOCATED AT TOP OF DROP NOT NEAR FIXTURES | | IN AN "EFFECTIVE RANGE" AS REQUESTED IN | | PREVIOUS REVIEW. | | 4) RPZ BACKFLOW REQUIRED ON WATER SERV- | | ICE. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|