2002-02-07 00:00:00 | BUILDING PLAN REVIEW |
| *******DENIED******* |
| ROBERT BROWN(561) 659 8096 EXT 8499 |
| |
| NIETHER STANDARD BUILDING CODE 1997 OR |
| FLORIDA BUILDING CODE 2001 ARE STATED ON |
| THE PLANS.THE PLANS HAVE BEEN REVIEWED |
| FOR COMPLIANCE WITH STANDARD BUILDING |
| CODE 1997 AS PER TELEPHONE CONVERSATION |
| WITH MPA ARCHITECTS', RICHARD LOGAN |
| |
| SBC = STANDARD BUILDING CODE 1997 |
| SBC*= STANDARD BUILD'G CODE (CITY AMEND) |
| |
| 1) SBC* 104.1.1A SEPARATE PERMIT |
| APPLICATION WILL BE REQUIRED FOR THE NEW |
| CANOPY. |
| |
| 2) SBC 1012.4HORIZONTAL SLIDING DOORS |
| IN A MEANS OF EGRESS.THE AUTOMATIC |
| SLIDING ENTRANCE DOORS SHALL COMPLY WITH |
| THE REQUIREMENTS, STATED IN THE CODE, |
| FOR SLIDING DOORS IN A MEANS OF EGRESS. |
| |
| 3) SBC* 104.2STAIRCASE/ELEVATOR LOBBY. |
| SUBMIT DETAILS TO DESCRIBE THE FINISHED |
| FLOOR LEVELS, IN THIS AREA, FOLLOWING |
| REMOVAL OF THE EXISTING RAMP BETWEEN THE |
| STAIRCASE AND THE ELEVATOR LOBBY. |
| |
| 4) SBC* 1606.4 AND SBC 2405NEW STORE- |
| FRONT.THE PLANS STATE THAT 1/4" THICK |
| TEMPERED GLASS IS TO BE USED BUT, TO |
| COMPLY WITH THE CONDITIONS OF THE |
| PRODUCT APPROVAL, THE GLASS SHALL BE |
| 9/16" THICK LAMINATED GLASS (0.09 INTER- |
| LAYER BETWEEN TWO LAYERS OF 1/4" THICK |
| HEAT STRENGTHENEND GLASS).AMEND THE |
| PLANS TO AVOID CONFUSION. |
| |
| 5) SBC 2405SHEET A-6, DOOR SCHEDULE. |
| ANY GLAZING IN DOORS, INLUDING THE |
| ELEVATOR DOOR AND ADJACENT GLAZED PANEL, |
| IS IN A 'HAZARDOUS LOCATION' AND IS |
| REQUIRED TO BE SAFETY GLASS SATISFYING |
| THE REQUIREMENTS OF THE CONSUMER PRODUCT |
| SAFETY COMMISSION 16, CODE OF FEDERAL |
| REGULATIONS, PART 1201 (CPSC 16-CFR, |
| PART 1201).SUBMIT DETAILS TO |
| DEMONSTRATE COMPLIANCE. |
| |
| **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| |
| END OF REVIEW COMMENTS |