Plan Review Notes For Permit 02010758 |
Permit Number |
02010758 |
|
Review Stop |
R |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2002-02-14 00:00:00 | ************BUILDING PROVISO************ | | | | 1) THERE IS A DISCREPANCY AS TO THE TYPE | | OF COLUMN FOR THE OPTIONAL COVERED | | PORCH INDICATED ON SHEET O1L. SECTION A | | STATES 3-1/2"X 3-1/2"X 1/4" STRUCTURAL | | ALUMINUM COLUMN AND DETAIL B STATES 3"X | | 3"X 1/4" STEEL COLUMN. PLEASE SUBMIT AN | | ENGINEERED SHOP DRAWING OF THE COLUMN | | THAT IS USED. PLEASE CORRECT THIS ON THE | | PLANS FOR FUTURE SUBMITTALS. | | | | 2)FOR FUTURE SUBMITTALS, PLEASE INDICATE | | ON THE COVERED PORCH SECTION ON SHEET | | O1L THAT THE METAL LATH IS REQUIRED TO | | BE ATTACHED WITH NAILS OR STAPLES THAT | | PROVIDE AT LEAST 1-3/4" PENETRATION INTO | | HORIZONTAL WOOD FRAMING MEMBERS PER | | ASTM C-1063. |
|