2002-01-29 00:00:00 | CHECKLIST: |
| 1-NEED RECORDED NOTICE OF COMMENCEMENT. |
| 2-PAY IMPACT FEES AND BRING PAID RECEIPT |
| 3-CLARIFY LOCATION OF SHEARWALL SEGMENTS |
| AND DIMENSIONS. SEE ELEVATIONS AND |
| 2ND. FLOOR FRAMING PLAN. |
| -CLARIFY FASTENING AT ENDS OF SHEARWALL |
| -CLARIFY WHY THERE ARE NOT SHEARWALLS |
| AT FRONT ELEVATION? |
| -HOW ARE CORNERS AT 2ND FL. REINFORCED? |
| 4-FIRST FLOOR BATH TO HAVE DOOR THAT |
| PROVIDES 29" MIN. CLEAR OPENING. SEC. |
| 11 OF FLORIDA ACCESSIBILITY CODE, 1997 |
| 5-PROVIDE ATTIC ACCESS AT LANAI ROOF. |
| SEC. 2309.6 SBC 1997. |
| 6-SHOW RAILINGS AT STAIRS. SEC. 1007.5 |
| -SPECIFY FASTENERS FOR GUARDRAILS AND |
| HANDRAILS THAT SATISFY THE DESIGN |
| REQUIREMENTS OF SEC. 1608.2 SBC 1997. |
| 7-SPECIFY BEAM ABOVE BREAKFAST AREA AND |
| END CONNECTORS. SEC. 104.2.2 CITY |
| AMENDMENTS AND SEC. 1606 SBC 1997. |
| 8-COMPLETE STEEL COLUMN DETAIL. SPECIFY |
| TOP AND BOTTOM ATTACHMENTS. SECTION |
| 104.2.2 CITY AMENDMENTS TO SBC 1997 & |
| SEC. 1606 SBC 1997. |
| 9-PROVIDE STRUCTURAL BUCK DETAIL FOR |
| EXTERIOR SWING DOORS. SEC. 104.2.2 |
| CITY AMENDMENTS TO SBC 1997. |
| 10-SOIL TEST REPORT TO HAVE ENGINEER'S |
| ORIGINAL SIGNATURE (NOT RUBBER STAMP) |
| AS REQUIRED BY CHAPTER 471 FL STATUTES |
| 11-LEFT SIDE EXTERIOR ELEVATION DOESN'T |
| MATCH FLOOR PLANS. SEE WINDOWS AND |
| DOORS NOT SHOWN. |
| -CLARIFY PITCH OF ROOF. SEE ELEVATIONS. |
| 12-PROVIDE PRODUCT APPROVAL FOR: |
| A)ENTRY DOORS. |
| B)HORIZONTAL ROLLING WINDOWS (DRAWINGS |
| ARE NOT LEGIBLE). |
| C)SINGLE HUNG WINDOWS. |
| D)SLIDING GLASS DOORS(DWGS NOT LEGIBLE). |
| E)ARCHED WINDOWS. SEE SIZES ON PLANS. |
| F)WINDOW MULLIONS. |
| G)AWNING WINDOWS. |
| H)ROOF TILE. |
| |
| 13-SPECIFY THE DESIGN PRESSURES THAT |
| WERE CALCULATED AT EACH EXT. OPENING. |
| SEC. 1606 SBC 1997. |
| 14-REVISE THE OWNER INFORMATION IN THE |
| ENERGY CALCULATIONS AND COMPLETE ALL |
| INFORMATION ON TOP OF FORM. |
| 15-SPECIFY FASTENINGS FOR RAILINGS AND |
| GUARDRAILS TO COMPLY WITH SECTION |
| 1608.2 SBC 1997. |
| -SHOW RAILINGS ON PLANS. SECTION |
| 1007.5 SBC 1997. |
| 16-SPECIFY CEILING INSTALLATION AT ENTRY |
| AND REAR PORCHES. SEE ASTM C926 AND |
| ASTM C1063 FOR PROPER SPECIFICATIONS. |
| SEC. 2504.2SBC 1997. |
| 17-SEE COMMENTS ON PLANS, INCLUDING |
| COMMENTS BY THE OTHER TRADES. |
| -PLEASE BRING BACK REVIEWED SET AFTER |
| CORRECTIONS ARE DONE TO THE ORIGINAL |
| DRAWINGS IN ORDER TO EXPEDITE THE |
| REVIEW PROCESS. |
| 18-STORM PANELS: |
| A)PROVIDE COMPLETE INSTALLATION SCHEDULE |
| AS PER CITY SAMPLE ATTACHED. |
| B)PROVIDE KEY PLAN THAT MATCHES ACTUAL |
| ARCHITECTURAL PLANS. |
| C)STORM SHUTTERS PRODUCT APPROVAL IS |
| GOOD FOR ONE PERMIT ONLY. SEE NOTE ON |
| STORM SHUTTERS APPROVED DRAWINGS. |
| D)CLEARLY INDICATE ON STORM SHUTTER DWGS |
| THE SPECIFIC MOUNTING CONDITIONS AND |
| ANCHOR TYPE AND SPACING TO BE USED |
| ACCORDING TO THE MEAN ROOF HEIGHT, |
| DESIGN PRESSURES, PANEL SPAN, EDGE |
| DISTANCE AND STRUCTURE TO BE ATTACHED |
| TO (WOOD OR CONCRETE BLOCK). |