2002-01-12 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) MINIMUM FACILITIES FOR OFFICE SPACE
 OK, BUT WAREHOUSE USE IS UNCLEAR. WHAT
 TYPE OF WAREHOUSING IS GOING TO BE IN
 THIS SPACE. ACCORDING TO SHT A1, 43
 PEOPLE WILL BE WORKING IN THE WAREHOUSE.
 FACILITIES SHALL BE REQUIRED FOR THOSE
 PEOPLE ALSO AT A RATE OF 2 MALE W/C'S &
 2 LAVS AND 2 FEMALE W/C'S & 2 LAVS. 1
 DRINKING FOUNTAIN IS REQUIRED FOR WARE-
 HOUSE ALSO.
 2) SHTS A4 & A5 RESTROOMS 104 & 114. PER
 FACBC SEC 4.22.2 & 4.22.3 DOORS TO AN
 ADAPTABLE TOILET SHALL NOT SWING INTO
 THE CLEAR FLOOR SPACE OF ANY FIXTURE.
 3) SHTS A4 & A5. MINIMUM FACILITIES SHOW
 2 DRINKING FOUNTAINS REQUIRED. A HI-LOW
 IS CONSIDERED 1 FIXTURE. 1 MORE DRINKING
 FOUNTAIN IS REQUIRED. SPC TABLE 407
 4) SHTS A4 & A5, MENS RESTROOM HDCP
 STALL, W/C SHALL BE LOCATED IN THE COR-
 NER DIAGONAL FROM STALL DOOR. FACBC SEC
 4.17.3(2).
  
 REVIEW BY KEN STEVENS