Plan Review Notes For Permit 01120918
Permit Number 01120918
Review Stop P
Sequence Number 1
Notes
Date Text
2001-12-29 00:00:00DENIED;
 1.SHOW EXISTING BUILDING DRAIN (SIZE)
 AND LOCATION. ALSO WHERE NEW PLUMBING
 WILL TIE INTO.
 2.RISER DIAGRAM ARE NOT TO CODE;
 2ND FL. WATER CLOSET FLUSHES PAST
 THE BIDET.
 ATTIC BATH 3" MIN. PIPE REQUIRED
 FOR A WATER CLOSET.
 3.LAUNDRY AND MECH ROOMS MAYBE TOO SMALL
 FOR GAS APPLIANCES. SEE "CONFINED
 SPACE" IN THE 97 SMC CHAPTER 2. USE
 FOURMULA OF 50 CU. FT. PER 1000 BTU"S
 TO FIND AREA REQUIRED. VENTS MY BE
 REQUIRED.
 4.A SEPORATE GAS PERMIT IS REQUIRED. GAS
 CONTRACTOR TO SUBMIT PLANS WITH PERMIT
 APPLICATION.
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8369