Notes |
Date |
Text |
2001-12-29 00:00:00 | DENIED; | | 1.SHOW EXISTING BUILDING DRAIN (SIZE) | | AND LOCATION. ALSO WHERE NEW PLUMBING | | WILL TIE INTO. | | 2.RISER DIAGRAM ARE NOT TO CODE; | | 2ND FL. WATER CLOSET FLUSHES PAST | | THE BIDET. | | ATTIC BATH 3" MIN. PIPE REQUIRED | | FOR A WATER CLOSET. | | 3.LAUNDRY AND MECH ROOMS MAYBE TOO SMALL | | FOR GAS APPLIANCES. SEE "CONFINED | | SPACE" IN THE 97 SMC CHAPTER 2. USE | | FOURMULA OF 50 CU. FT. PER 1000 BTU"S | | TO FIND AREA REQUIRED. VENTS MY BE | | REQUIRED. | | 4.A SEPORATE GAS PERMIT IS REQUIRED. GAS | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT | | APPLICATION. | | | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT. 8369 |
|