2002-01-07 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT# 01120918 |
| 727 SUNSET RD. |
| CONT.: ROGER G. THOMAS |
| TEL: (561)575-1389 |
| |
| SBC= 1997 STANDARD BUILDING CODE |
| SBC*= AMENDMENTS/ STANDARD BUILDING CODE |
| |
| 1)- NOTICE OF COMMENCEMENT MUST BE RE- |
| CORDED AT THE COUNTY COURTHOUSE BEFORE |
| THE PERMIT MAY BE ISSUED. |
| |
| 2)- SBC 1804.2.7.2 SOILS TEST TO VERIFY |
| THE MINIMUM SAFE BEARING VALUE. |
| |
| 3)- ADDITIONAL INFORMATION REQUIRED: |
| AVERAGE EAVE HEIGTH= |
| BASIC PRESSURE= |
| SHEET A-2 MISSING THIS INFORMATION. THE |
| PRESSURE ZONES FOR ALL EXTERIOR OPENINGS |
| (WINDOWS & DOORS) SHOW ON ELEVATIONS. |
| |
| 4)-MISSING ENERGY CALCS, |
| |
| 5)- SHEET A-4 DEPICTS A THIRD STORY, |
| ATTIC LOFT AND FUTURE BATH, THIS WOULD |
| REQUIRE THIS STRUCTURE TO BE A TYPE VI |
| 1-HOUR PROTECTED BUILDING. |
| A) TABLE 600 TYPE V1 PROTECTED INDICATE |
| THE 1 HR PROTECTION FOR ALL STRUCTUR |
| AL MEMBERS AS REQUIRED BY TABLE 600. |
| B) GIVE A CUT SECTION THROUGH THE 3 |
| FLOORS INDICATING THE HEIGTH OF EACH |
| STORY, SBC 1203.2.1 OCCUPLIABLE ROOMS |
| AND HABITABLE SPACES SHALL NOT HAVE A |
| CEIL LESS THAN 7'-6", STORAGE, BATHROOMS |
| MAY BE 7'-0". IF ANY ROOM IN A BUILDING |
| HAS A SLOPING CEILING, THE PRESCRIBED |
| CEILING HEIGTH FOR THE ROOM IS REQUIRED |
| IN ONLY 1/2 THE AREA THEREOF.(1203.2.2) |
| 6) SHEET A-6 |
| DISCREPANCY BETWEEN FLOOR PLAN NEW |
| WINDOWS AND SHEETS 5/SHEET6. IN REVIEW- |
| ING PLANS WITH HISTORICS THEY INDICATE |
| THAT NEITHER DRAWING IS CORRECT BUT |
| CASEMENT WINDOWS SHALL BE INSTALLED? |
| |
| 7) SHEET A-5 INDICATES WINDOWS WITH MULL |
| ION, WINDOW REPORT INDICATES THAT THIS |
| REPORT IS FOR SINGLE UNIT APPLICATION. |
| REPORT REQUIRED FOR MULLION. |
| |
| 8) FRENCH DOOR REPORT SHALL REQUIRE |
| LARGE MISSLE IMPACT RESISTANCE PROTEC- |
| TION. |
| |
| 9) SHEET A-11 THE FIRST FLOOR FRAMING |
| PLAN INDICATES A DOUBLE 2X12 BEAM AROUND |
| THE PERIMETER OF THE PORCH, WHAT TYPE |
| OF SUPPORT IS USED WHERE WOOD BEAM ENDS |
| AT WALL LINE? SECTION OF KITCHEN WHERE |
| WALL WAS REMOVED, WHAT TYPE OF CONNEC- |
| TION IS TO BE USED FOR 6X6 POST AND FOR |
| GIRDER, DOES THE EXISTING 2ND FLOOR |
| JOIST BEAR ON THIS WALL? |
| |
| 10)- SHEET A-7 SECTION 2 STORY INDICATES |
| STUCCO ALL THE WAY TO THE GROUND, A 6" |
| AIR GAP REQUIRED TERMITE PROTECTION, |
| SBC2304.2.5 AMENDMENTS. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| (561)659-8096X8412 |