Plan Review Notes For Permit 01111005 |
Permit Number |
01111005 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2001-12-07 00:00:00 | DENIED | | REFERENCE: SPC-94-SBC-97 | | | | 1) SANITARY RISER DIAGRAM DOES NOT MATCH | | FLOOR PLAN. STACK FOR BATH #2 UPSTAIRS | | SHOULD BE TAKEN OFF BEFORE W/MACHINE. | | 2) W/MACHINE NOT VENTED ON RISER DIAG. | | 3) LAV IN POWDER ROOM NOT VENTED ON DIAG | | 4) 3" STACK NOT ALLOWED IN BLOCK WALL & | | CAN NOT PASS THRU TIE BEAM. SBC-97 SEC | | 1907.3.5 | | 5) TUB NOT VENTED IN BATH #2, SPC SEC | | 913.2 | | 6) DISH WASHER DRAIN SHALL GO TO GARBAGE | | DISPOSAL OR TAILPIECE ON KITCHEN SINK. | | 7) DISCHARGE FROM MASTER BATH SHALL NOT | | DRAIN INTO VENT STACK FOR KITCHEN SINK. | | SPC SEC 913.2 & 910.2. SEPARATE VENT RE- | | QUIRED FOR KITCHEN SINK. | | 8) RUNNING TRAPS IN MASTER BATH TUB NOT | | ALLOWED. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|