2001-11-22 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT # 01110457 |
| 6200 S DIXIE HWY |
| CONT: DUANE THOMAS INCORP |
| TEL: (561)575-0610 |
| |
| SBC= 1997 STANDARD BUILDING CODE |
| SBC*= AMENDMENTS/ STANDARD BUILDING CODE |
| FL ACC CODE= FLORIDA ACCESSIBILITY CODE |
| |
| 1)- SBC104.2.2* PLEASE PROVIDE AN OVER |
| ALL PLOT PLAN INDICATING THE LOCATION |
| OF THE TENANT SPACE IN RELATIONSHIP TO |
| THE BUILDING. |
| |
| 2)- SBC1004.1.4 WHERE TWO OR MORE EXITS |
| OR EXIT ACCESS DOORS ARE REQUIRED, AT |
| LEAST (2) OF THE EXITS OR EXIT ACCESS |
| DOORS SHALL BE PLACED A DISTANCE APART |
| NOT LESS THAN ONE HALF OF THE LENGTH OF |
| THE MAXIMUM OVERALL DIAGONAL DIMENSION |
| OF THE BUILDINGOR AREA TO BE SERVED |
| MEASURED IN A STRAIGHT LINE BETWEEN SUCH |
| EXITS OR EXIT ACCESS DOORS. |
| |
| 3)- SBC 1001.1.3 THE EXTERIOR DOORS |
| LEADING FROM THE KITHEN CAN NOT BE CONSI |
| DERED AS EXITDOORS FOR THE PUBLIC |
| SINCE THIS CODE ARTICLE RESTRICTS IT. |
| |
| 4)- THIS BUILDING IS A (2) STORY BUILD- |
| ING. INDICATE HOW THE 2 HR ASSEMBLY |
| TENNANT SEPERATION IS ACCOMPLISHED? |
| (SBCTABLE 704.1.) FIRST FLOORCEILING ASS |
| EMBLY TO SECOND FLOOR FLOOR?UL LISTING? |
| INDICATE WHERE THE GREASE VENTS & CHASES |
| ARE AND SEPERATION FROM THE SECOND FLOOR |
| TENANT? |
| |
| 5)- SBC 1204.2 THE WALLS & FLOORS OF ALL |
| PUBLIC REST ROOMS SHALL BE LINED WITH |
| NONABSORANT MATERIAL TO A HEIGTH OF 4'-0 |
| ABOVE THE FLOOR. |
| |
| 6)- 1203.4.2 EVERY TOILET ROOM SHALL |
| HAVE A WINDOW OR APPROVED MECHANICAL |
| VENTILATION. |
| |
| 7) FL ACC CODEFLOOR FINISHES:4.5 |
| FLOOR SURFACES ALONG ACCESSIBLE ROUTES |
| AND IN ACCESSIBLE ROOMS AND SPACES |
| INCLUDING FLOORS WALKS AND RAMPS SHALL |
| BE STABLE, FIRM AND SLIP RESISTANT. |
| ADDAAG A-5 A STATIC COEFFICIEENTOF FRIC- |
| TION OF 0.6 FOR ACCESSIBLE ROUTES & |
| 0.8 FOR RAMPS. |
| |
| THESE PLANS ARE NOT THOROUGH ENOUGH TO |
| DO A COMPLETE REVIEW. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| (561) 659-8096 X8412. |