2001-12-04 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE
 SBC* = STANDARD BUILDING CODE (AMENDMENT
 S)
 FL ACC CODE = FLORIDA ACCESSIBILITY CODE
 FL ENERGY CODE = FLORIDA ENERGY EFFICIEN
 CY CODE FOR BUILDING CONSTRUCTION
  
 1) SBC* 104.2.1REAR AND SIDE
 ELEVATIONS SHALL BE SUBMITTED TO SHOW
 THE ROOF PROFILE AND DOOR AND WINDOW
 ARRANGEMENTS.
  
 2) FL ENERGY CODE 103.0CODE COMPLIANCE
 CERTIFICATION FORMS SHALL BE SUBMITTED
 UNLESS THE BUILDING IS NEITHER HEATED
 NOR COOLED BY MECHANICAL SYSTEMS, AND
 THEREFORE EXEMPT AS DESCRIBED IN PART
 VIII OF CHAPTER 553, FLORIDA STATUTES
 (SS. 553.902(1)(B) AND 553.903).
  
 3) FL ACC CODE 4.23.2THE BATHROOM DOOR
 SHALL HAVE A MINIMUM CLEAR OPENING OF
 29 INCHES.
  
 4) SBC* 1707.4PRODUCT APPROVAL
 DOCUMENTS FOR THE NEW EXTERNAL DOOR AND
 WINDOWS SHALL BE SUBMITTED.
  
 5) SBC 2405.2.1(2) AND (4)GLAZING IN
 HAZARDOUS LOCATIONS IS REQUIRED BY
 SBC 2405.1 TO PASS THE IMPACT AND OTHER
 LOAD TEST REQUIREMENTS OF CPSC (U.S.
 CONSUMER PRODUCT SAFETY COMMISSION)
 16-CFR, PART 1201.
  
 6) SBC 2308.1SPECIFY THE SPACING OF
 THE STUDS TO ENSURE COMPLIANCE WITH
 TABLE SBC 2308.1.
  
 7) TYPICAL SECTION.THE PROPOSED TRUSS
 ANCHOR "SIMPSON ETA 18" DOES NOT APPEAR
 TO BE A VALID SIMPSON OR USP REFERENCE.
 PRODUCT DETAILS OR CORRECT REFERENCE
 REQUIRED.