Plan Review Notes For Permit 01101438 |
Permit Number |
01101438 |
|
Review Stop |
R |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2002-01-22 00:00:00 | APPROVED WITH PROVISO: | | 1-FLOOD ZONE AO. NEED THE ELEVATION | | CERTIFICATE. | | 2-PROVIDE ENTRY DOORS PRODUCT APPROVAL | | WITH LEGIBLE DRAWINGS. | | 3-ENGINEER OF RECORD TO REVISE THE | | STRUCTURAL BUCK DETAIL SHOWING A 2X | | BUCK DETAIL AS REQUIRED ON THE PRODUCT | | APPROVAL USED FOR ENTRY DOORS. | | 4-TRUSS DRAWINGS 2ND REVIEW: | | *CONTRACTOR CHANGED TRUSS COMPANY. | | A)UPDATE ALL GENERAL TRUSS DETAILS. | | B)THERE ARE 2 ENGINNERS SEALING THE | | GENERAL TRUSS DETAILS. COMPLY WITH | | REQUIREMENTS OF FLORIDA ENGINEER BOARD | | WHEN AN ENGINEER'S TAKEN OTHER'S WORK. | | C)PROVIDE LEGIBLE & COMPLETE GENERAL | | TRUSS DETAILS. | | D)ENGINEERED TRUSSES ARE DESIGNED USING | | ASCE 7-98. NEED TO USE THE RIGHT WIND | | ZONE. IT IS 140MPH, NOT 110 MPH WIND. | | -ALSO, USE THE MEAN ROOF HEIGHT. THIS | | BLDG HAS AN SLOPED ROOF, NOT FLAT ROOF |
|