Date Text
2002-03-15 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED THE ELEVATION
 CERTIFICATE.
 2-FOR FUTURE SUBMITTALS SPECIFY ON PLANS
 THAT GLASS BLOCK NEEDS TO BE ONE HOUR
 FIRE RATED ASSEMBLY FOR WALLS ON THE
 ZERO LOT LINE. TABLE 600 SBC 1997.
 3-PROVIDE COMPLETE STRUCTURAL DETAIL AND
 SPECIFICATIONS FOR INSTALLATION OF
 HANGING AIR HANDLER UNITS.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 AND SEC. 1603 SBC 1997.
 4-SPECIFY CEILING INSTALLATION AT FRONT
 AND BACK PORCH. SPECIFY ALL FASTENERS.
 SEE ASTM C-1063.
 SEC. 2504.2 SBC 1997.