2001-11-19 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT # 01101223 |
| 647 57TH STREET |
| CONT: RITEWAY INSURANCE REPAIR |
| CGC-048689 |
| TEL: (954) 923-3677 |
| |
| SBC= 1997 STANDARD BUILDING CODE |
| SBC*= AMENDMENTS/ STANDARD BUILDING CODE |
| |
| 1)- FL. S.S. 489.113(3B)/(3G) STATE |
| CONTRACTOR CAN NOT INSTALL ROOF SHINGLES |
| ON A REMODEL, ONLY ON NEW ROOF. |
| |
| 2)- MISSING ROOFING PRODUCT APPROVAL |
| FOR ROOFING SYSTEM. SBCCI OR DADE COUNTY |
| PRODUCT APPROVAL REQUIRED UNDER SEPERATE |
| PERMIT WITH ASSOCIATED FEES. |
| |
| 3)- SBC 1606.2.6.2COMPONENTS & CLADDING |
| (2) COPIES OF PRODUCT APPROVALS WILL BE |
| REQUIRED FOR ALL EXTERIOR OPENINGS, |
| EITHER SBCCI OR DADE COUNTY PRODUCT |
| APPROVAL REQUIRED; |
| WINDOWS |
| SWING DOORS |
| GARAGE DOORS OVERHEAD OR ROLL UP |
| SKYLIGHTS |
| STORM SHUTTERS. |
| |
| 3)- SBC 1005.4.1:EVERY SLEEPING ROOM |
| ON THE FIRST FLOOR WILL REQUIRE EMERGEN- |
| CY ESCAPE AND RESCUE OPENINGS, STATE |
| SIZE. |
| |
| 4)- SBC 1707.4: GLAZED OPENINNGS REQUIRE |
| 1.5 TIMES THE DESIGN PRESSURE, TEST |
| REPORT FOR WIND, SEE ATTACHMENT. |
| |
| 5)- SBC 1606.4.1*/ 1707.4.1* GLAZED |
| OPENINGS WILL REQUIRE EITHER IMPACT |
| RESISTANT GLAZING OR STORM SHUTTERS |
| PASSING THE LARGE MISSLE IMPACT TESTING |
| REQUIREMENTS, WITH CITY REQUIREMENTS |
| KEY PLAACEMENT PLAN & INSTALLATION SCHED |
| ULE, SEE ATTACHMENT. |
| |
| 6)- SBC 1606.2.6.1 MAIN WIND FORCE RESIS |
| TING SYSTEM. INDICATE WHAT TYPE OF |
| FASTENERS ARE TO BE USED TO RESIST VERTI |
| CAL AND HORIZONTAL WIND LOADS AND INDICA |
| TE THE LOADS THAT EACH TYPE OF MECHANISM |
| SHALL BE CAPABLE OF RESISTING. |
| |
| 7)- CITY CODE 7.2 PERMIT FEES SHALL BE |
| CALCULAETED USING THE STANDARD BUILDING |
| CODE EVALUATION TABLES LATEST EDITION. |
| 832 SQ FT= $65345.00X .60 ( REMODEL)= |
| $ 39,207.00 ADDITIONAL FEES DUE. |