Date |
Text |
2001-11-05 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT# 01091672 |
| 1025 21 ST ST |
| HABITAT FOR HUMANITY |
| (561) 833-9665 |
| |
| SBC= 1997 STANDARD BUILDING CODE |
| SBC*= AMENDMENTS/STANDARD BUILDING CODE |
| |
| 1)- PERMIT APPLICATION TO BE SIGNED BY |
| THE PERSON WHICH WILL PROVIDE THE |
| QUALIFIED SUPERVISION. |
| |
| 2)- SBC* 104.2.2 A RECENT SURVEY. IF PRO |
| PERTY IS LOCATED IN A "A" ZONE MINIMUM |
| ELEVATION CERTIFICATE WILL BE REQUIRED. |
| THIS LOT IS LOCATED IN A "B" ZONE. |
| |
| 3)-SBC* 1804.2.7.2 SOILS REPORT/ W THE |
| MINIMUM SAFE BEARING VALUE. |
| |
| 4)- SBC 2304.1.2 SOIL TREATMENT FOR |
| TERMITES FOR SLAB ON GRADE, TREATMENT OF |
| SOIL REQUIRED BEFORE THE PLACEMENT OF |
| CONCRETE. |
| |
| 5)- SBC 1606.2.6.2 COMPONENTS & CLADDING |
| PRODUCT APPROVAL REPORTS (2 COPIES) |
| ARE REQUIRED FOR THESE ITEMS: |
| A) GLAZED OPENINGS |
| B) MULLIONS FOR WINDOWS |
| C) EXTERIOR DOORS- MISSING |
| D) ROOFING ASSEMBLIES-SHINGLES MISSING |
| PRODUCT TESTING REPORT FOR 110 MPH |
| |
| 6)- SHEET A-3 FRONT PORCH DETAIL, GAL. |
| POST ANCHOR SIMPSON AB-44, ANCHOR BOLT |
| MISSING INFORMATION. IS DERATING TO BE |
| A FACTOR LESS THAN 2" FROM EDGE? |
| |
| 7)- STORM SHUTTERS WPB INTERPRETATION |
| REQUIRES A KEY PLAN & FASTENING SCHEDULE |
| WITH THE PRODUCT APPROVAL REPORT SEE |
| SAMPLE ATTACHED. |
| |
| 8)- CALC VALUE: |
| LIV. 1340 X 49.92=$66,892.80 |
| NON194 X 28.08= 5,447.52 |
| $72,340.32 |
| TOTAL CALC VALUE $72,340.00 |
| |
| STATE RADON FEES $ 15.34 |
| ADDITIONAL PERMIT FEES $326.63 |
| JAN 1,2002 PLANS WILL BE REVIEWED UNDER |
| THE 2001 FLORIDA BUILDING CODE FOR PLANS |
| SUBMITTED AFTER THAT DATE. |
| |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| (561) 659-8096 X8412 |