2002-12-11 00:00:00 | RE: ROOF TILE NOA 99-1012.01. | | | | THE NOA HAS HIGH LIGHTED ON IT TABEL 4A | | FOR A SINGLE PATTY ADHESIVE SYSTEM. | | | | SECTION 3 LIMITATIONS, REQUIRES A | | STATIC FIELD UPLIFT TEST IN ACCORDANCE | | WITH MIAMI DADE RAS 106.THE RESULTS | | OF THIS TESTING MUST BE PROVIDED TO THE | | CITY. | | | | DOCUMENTATION OF THE QUARTERLY TESTING | | AS SET OUT IN THE REPORT MUST ALSO BE | | PROVIDED TO THE CITY. | | | | PRIOR TO ANY INSTALLATION, AN ANALYSIS | | IN ACCORDANCE WITH MIAMI-DADE RAS 127 | | FOR A MOMENT BASED SYSTEM USING THE | | PRESSURE FOR THE CORNER ZONE MUST BE | | BE PROVIDED BY G.V. PIREZ, PE.THE | | SHEET DATED 9/15/01 HAS PRESSURES OF | | -112 FOR ZONE 1 AND -182 FOR ZONE 2. | | THE CORNERS OR ZONE THREE ARE ABSENT | | FROM THAT SHEET AND THE MR APPEARS | | MARGINAL. |
|