2001-10-02 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: REQUIRED/ |
| CHANGE OF OCCUPANCY |
| RESIDENTIAL TO |
| BUSINESS |
| OWNER: GAY CINQUE |
| TEL: 835-1584 |
| |
| 1)- SBC AMENDMENTS 104.1.1 / 3401.2.2. |
| CHANGE OF OCCUPANCY OF ANY EXISTING |
| BUILDING OR STRUCTURE, THE BUILDING, |
| ELECTRICAL, GAS, MECHANICAL & PLUMBING |
| SYSTEMSSHALL BE MADE TO CONFORM TO THE |
| INTENT OF THE TECHNICAL CODES AS |
| REQUIRED BY THE BUILDING OFFICIAL. |
| |
| 2)- SBC 3401.2.2.2.CHANGES IN OCCUPANCY |
| OF A BUILDING NOW EXISTING OR HEREAFTER |
| ERECTED SHALL NOT BE MADE UNTIL A RE- |
| VISED CERTIFICATE OF OCCUPANCY HAS BEEN |
| ISSUED. A DESIGN PROFESSIONAL WILL NEED |
| TO CERTIFY THE EXISTING FLOOR SYSTEM |
| FOR 50 LBS. LIVE LOAD DESIGNED FOR |
| BUSINESS USE. |
| |
| 3)- SBC 104.2.2. A PLOT PLAN SHALL BE |
| NECESSARY TO INDICATE THE PARKING THAT |
| WILL BE REQUIRED, HANDICAPPED PARKING, |
| ACCESS ISLE AND A ACCESSIBLE ROUTE INTO |
| THE STRUCTURE. THE BUILDING OFFICIAL |
| SHALL DETERMINE THE EXTENT OF THE ACCESS |
| IBILTY, IF THE 20 % DISPROPORTIONATE |
| COST RULE IS IN EFFECT OR IF THE CHANGE |
| OF OCCUPANCY WILL REQUIRE THE ENTIRE |
| STRUCTURE TO BE CONSIDERED "NEW CONSTRUC |
| TION". |
| FL ACC CODE 4.1.6 THIS EDITION OF THE |
| CODE DOES NOT APPLY TO BUILDINGS OR FA- |
| CILITIES WHICH WERE IN EXISTANCE ON OCT. |
| 1, 1997 UNLESS: (I) THE BUIULDING, IS |
| BEING CONVERTED FROM RESIDENTIAL TO |
| NONRESIDENTIAL OR MIXED USE, AS DEFINED |
| BY LOCAL LAW. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| (561) 659-8096 X 8412 |
| THE BUILDING OFFICIAL SHALL BE OUT OF |
| THE OFFICE UNTIL OCT.4/01. UPON ARRIVAL |
| THIS MATTER WILL BE DISCUSSED & TO WHAT |
| EXTENT THE TECHNICAL AS WELL AS THE |
| ACCESSIBILITY CODE WILL NEED TO COMPLY. |