Notes |
Date |
Text |
2001-11-05 00:00:00 | DENIED | | REFERENCE: SPC-94 - FHA AMEND 98 DESIGN | | MANUAL | | 1) PAGES 1, 1A, 1B MODEL 1527 (L)(R). | | M/BATH SHOWS 1'7" TO C/L OF W/C AND IT | | SHOULD BE 1'6". ALSO SHOW CLEAR FLOOR | | SPACE FOR LAV. | | 2) PAGES 1, 1A, 1B MODEL 1527 (L)(R). | | 2ND BATH SHOW CLEAR FLOOR SPACE FOR W/C | | AND LAV. | | 3) PAGES 1, 1A, 1B MODEL 1409 (L)(R). | | M/BATH SHOWS 1'7" TO C/L OF W/C AND IT | | SHOULD BE 1'6". ALSO SHOW CLEAR FLOOR | | SPACE FOR LAV. | | 4) PAGES 1, 1A, 1B MODEL 1409 (L)(R). | | 2ND BATH SHOWS 2'8" OPENING FOR W/C, AND | | MINIMUM OPENING REQUIRED IS 2'9". ALSO | | SHOW CLEAR FLOOR SPACE FOR W/C AND LAV. | | 5) PAGES 1, 1A, 1B MODEL 1357 (L)(R). | | M/BATH SHOWS 1'7" TO C/L OF W/C AND IT | | SHOULD BE 1'6". ALSO SHOW CLEAR FLOOR | | SPACE FOR LAV. | | 2ND BATH SHOW CLEAR FLOOR SPACE FOR W/C | | AND LAV. | | 6) PAGES 1, 1A, 1B GENERAL NOTES #11 - | | CHANGE TO READ FHA AMENDED 98 DESIGN | | MANUAL. | | 7) PAGE 2 MODELS 1409 (L)(R) AND 1527 | | (L)(R) PLUMBING RISERS. OPT LAUNDRY TRAY | | IS NOT VENTED PROPERLY. SHOW VENT FOR | | THESE FIXTURES. | | 8) CORRRECTIONS FOR SIGNED AND SEALED | | PLANS SHALL BE SIGNED AND SEALED ALSO. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|