Plan Review Notes For Permit 01090278 |
Permit Number |
01090278 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2001-11-14 00:00:00 | TRUSS DRAWINGS CHECKLIST: | | | | 1-ENGINEERED TRUSSES ARE DESIGNED USING | | DIFFERENT MEAN ROOF HEIGHTS. THERE | | IS ONLY ONE MEAN ROOF HEIGHT FOR | | ENTIRE BUILDING. REVIEW ALL ENGINEERED | | TRUSSES AND REVISE AS REQUIRED. | | TABLE 1606.2A SBC 1997. | | 2-SOME TRUSSES ARE DESIGNED USING "WALL | | HEIGHT" INSTEAD OF MEAN ROOF HEIGHT. | | WALL HEIGHT APPLIES ONLY TO FLAT ROOF | | SYSTEMS. MEAN ROOF HEIGHT IS USED FOR | | SLOPED ROOF. REVISE AS REQUIRED. | | | | NOTES: | | -THESE COMMENTS HAVE BEING ADDRESED ON | | PREVIOUS REVIEWS. | | -DRAWINGS TO BE FILED UNDER PERMIT # | | 01090278. | | -THESE COMMENTS APPLY TO PERMIT #S: | | 01090278, 01090280, 01090282, 01090284 | | AND 01090288. |
|