Plan Review Notes For Permit 01080081 |
Permit Number |
01080081 |
|
Review Stop |
M |
Sequence Number |
4 |
|
Notes |
Date |
Text |
2001-10-30 00:00:00 | *******************DENIED*************** | | | | | | PLEASE SUBMIT THE FOLLOWING INFORMATION | | FOR REVIEW. | | | | 1.INDICATE LOCATION OF SHAFT. | | | | 2.CLEANOUTS/ACCESS DOORS NOT INDICATED | | ON PLAN AS PER 1997 SMC 505.5.1. | | | | 3.PLAN SHEET 2 OF 3, SUPPLY DUCT | | LOOKS TO BE IN THE TRUSS AREA. | | PLEASE CLARIFY. | | | | 4.PLEASE INDICATE HOW GREASE DUCT IS | | BEING SUPPORTED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|