Date |
Text |
2001-08-07 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT # 0107579 |
| 423 4TH STREET 2ND & 3RD FL |
| |
| CONT: SISCA CONSTRUCTION |
| TEL: (561) 309-7175 |
| |
| 1)- EXTERIOR STEEL STAIRS : SBC 1006.2.4 |
| EXTERIOR STAIRS SHALL BE SEPERATED FROM |
| THE INTERIOR OF THE BUILDINGBY WALLS |
| WITH A FIRE RESISTANCE RATING OF NOT |
| LESS THAN 1 HR, WITH FIXED OR SELF-CLOS- |
| ING OPENING PROTECTIVES AS REQUIRED FOR |
| ENCLOSED STAIRS.THIS PROTECTION SHALL |
| EXTEND VERTICALLY FROM THE GROUND TO A |
| POINT 10 FT. ABOVE THE UPPER MOST LAND- |
| ING OR THE ROOF LINE, WHICHEVER IS LOWER |
| AND HORIZONTALLY 10 FT. FROM EACH SIDE |
| OF THE STAIRWAY. OPENINGS WITHIN 10 FT |
| HORIZONTAL EXTENSION OF THE PROTECTED |
| WALLS BEYOND THE STAIRWAY SHALL BE |
| FIXED 3/4 HR ASSEMBLIES. |
| |
| 2)- 3RD FLOOR STAIRS TO EXTERIOR: |
| SBC 1007.4.2, THE WIDTH OF LANDINGS |
| SHALL BE NOT LESS THAN THE WIDTH OFTHE |
| STAIRWAYS THEY SERVE. EVERY LANDING |
| SHALL HAVE A MINIMUM DIMENSION IN THE |
| DIRECTION OF TRAVEL EQUAL TO THE WIDTH |
| OF THE STAIRWAY. |
| |
| 3)- PENETRATIONS, SBC 705.6.1: THROUGH |
| PENETRATIONS OF FIRE RATED HORIZONTAL AS |
| SEMBLIES SHALL COMPLY WITH 705.6.1.1 OR |
| 705.6.1.2. SHOW COMPLIANCE. |
| |
| 4)- SBC TABLE 803.3 INTERIOR MINIMUM |
| FINISH CLASSIFICATION FOR WALLS &CEIL- |
| ING. |
| |
| 5)- RESTROOMS: SBC 1204.2: PUBLIC REST- |
| ROOMS SHALL BE LINED WITH AN NONABSORB- |
| ANT MATERIALFLOOR AND WALLS TO A HEIGTH |
| OF 4'-0". |
| |
| 6)- SBC 104.2.2 ADDITIONAL INFORMATION |
| REQUIRED, NEW CHASE PARTITION SHOW |
| UL RATING OR GYPSUM ASSOC RATING. |
| |
| 7)- OFFICE 201/202 FL ACCESIBILITY CODE |
| 4.13.6 MANEUVERING CLEARENCES AT DOORS, |
| SHOW HOW YOU ARE GOING TO ACHIEVE CODE |
| COMPLIANCE, SEE ATTACHMENT. THE SAME SIS |
| TUATION HAPPENS FOR DOOR 5 INTO THE |
| STAFF LOUNGE.OFFICE 208 & 301 REQUIRE |
| THE 18" SIDE CLEARENCE PLAN INDICATES |
| 17". |
| |
| 8)- AREA OF REFUGE SBC 1004.3.2.1 SHOW |
| COMPLIANCE FOR 2ND & 3RD FLOOR. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| (561) 659-8096 X8412 |