2001-08-02 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01070355
 1325 N CONGRESS
  
 CONT: MHS CONTRACTING
 TEL: 586-7063
  
 SBC= STANDARD BUILDING CODE
 1)- SBC 1012.5 DOORS OPENING ONTO EXIT
 ACCESS CORRIDORS, SHALL NOT REDUCE THE
 WIDTH OF THE CORRIDOR TO LESS THAN 1/2
 OF THE WIDTH DURING THE OPENING PROCESS.
 A- HALL CLOSET
 B- 2ND EGRESS IN THE WORK AREA (SINGLE
 DOOR)
  
 2)- SBC 803.3: INTERIOR FINISH CLASSIF-
 ICATION, SEE TABLE 803.3
  
 3)- SBC 903.2 FIRE SPRINKLER PLANS & LAY
 OUT ARE MISSING FROM THE PLANS.
  
 4)- SBC 1204.2 THE WALLS & FLOORS OF ALL
 PUBLIC RESTROOMS SHALL BE LINED WITH
 NONABSORBANT MATERIALS TO A HEIGTH OF
 4'-0".
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X 8412