2001-08-01 00:00:00PLUMBING PLAN REVIEW FOUNDATION PERMIT
 DENIED.
 (1) INFORMATION NEEDED TO REVIEW PLANS
 FOR A FOUNDATION PERMIT ONLY.
 (A) SHT'S S-01.02,P-1,P-2.
 (A) GARAGE DRAINS: TOTAL LOAD FROM UPPER
 FLOORS, SQUARE FOOTAGE,PIPE SIZES.
 (B)SANITARY SEWER: TOTAL LOAD IN FIXTURE
 UNITS,FROM UPPER FLOORS.WITH PIPE SIZES.
 (C) COMMON A/C CONDENSATE SYSTEM: LOAD
 FROM UPPER FLOORS WITH PIPE SIZES.
 CONNECT TO STORM DRAIN OUTSIDE OF BUILD-
 ING WITH A RELIEF VENT.MCWPC-94/804.4(6)
 (D) OIL SEPERATOR SIZED FOR LOAD ON
 SYSTEM,TO BE APPR BY WPB.ENGINEERING.
 (E) BACKFLOW PREVENTER LOCATION IN BUILD
 ING TO BE APPROVED BY WPB UTILITIES DEPT
 (F) IF ANY OF THE ABOVE COMMENTS ARE NOT
 IN THE FOUNDATION,PLEASE INDICATE WERE
 THEY ARE LOCATED IN THE BUILDING.
 END OF COMMENTS PAUL SCHMITZ