2001-06-07 00:00:00 | REVIEW NOTES: FAILED | | | | 1) PAGE 1A & PAGE 2 GENERAL NOTES #11 | | CHANGE TO READ FHA 1998 DESIGN MANUAL. | | | | 2) MODEL 1527 (L) & (R), M/B SHOWS 1'-7" | | TO CENTER OF W/C, AND IT SHOULD BE 1'-6" | | ALSO SHOW CLEAR FLOOR SPACE FOR LAV. | | PAGES 1A & 1B. | | | | 3) IN BATH #2 SHOW CLEAR FLOOR SPACE FOR | | W/C AND LAV. PAGES 1A & 1B. | | | | 4) MODEL 1409 (L) & (R), M/B SHOWS 1'-7" | | TO CENTER OF W/C, AND IT SHOULD BE 1'-6" | | ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND | | LAV. PAGES 1A & 1B. | | | | 5) BATH #2 SHOWS 2'8" OPENING FOR W/C. | | 2'9" MINIMUM SPACE REQUIRED FOR W/C. | | ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND | | LAV. PAGES 1A & 1B. | | | | 6) PLEASE SUBMIT A SANITARY RISER DIA- | | GRAM AS REQUIRED BY SPC-94 SEC. 104.2.1 | | AND SEC. 104.3.1 | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|