Plan Review Notes For Permit 01060061 |
Permit Number |
01060061 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2001-06-07 00:00:00 | REVIEW NOTES:FAILED | | | | 1) PAGE 1A & PAGE 2 GENERAL NOTES #11 | | CHANGE TO READ FHA 1998 DESIGN MANUAL. | | | | 2) MODEL 1527 (L) & (R), M/B SHOWS 1'7" | | TO CENTER OF W/C, AND IT SHOULD BE 1'6". | | ALSO SHOW CLEAR FLOOR SPACE FOR LAV. | | PAGES 1A & 1B. | | | | 3) IN BATH #2 SHOW CLEAR FLOOR SPACE FOR | | W/C AND LAV. PAGES 1A & 1B. | | | | 4) MODEL 1409 (L) & (R), M/B SHOWS 1'7" | | TO CENTER OF W/C, AND IT SHOULD BE 1'6" | | ALSO SHOW CLEAR FLOOR SPACE FOR LAV. | | PAGES 1A & 1B. | | | | 5) BATH #2 SHOWS 2'8" OPENING FOR W/C. | | 2'9" MINIMUM SPACE REQUIRED FOR W/C. | | PAGES 1A & 1B. | | | | 6) PLEASE SUBMIT SANITARY RISER DIAGRAM | | AS REQUIRED BY SPC-94 SEC. 104.2.1 & | | SEC 104.3.1 | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|