2001-06-14 00:00:00CHECKLIST:
 1-PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS: PRODUCT APPROVAL,
 DRAWINGS, KEY PLAN AND COMPLETE
 INSTALLATION SCHEDULE. SEE SAMPLE.
 2-SIZE OF BEDROOM WINDOW DOESN'T COMPLY
 WITH THE EGRESS REQUIREMENTS OF SEC.
 1005.4 SBC 1997.
 3-SPECIFY SIZE OF ATTIC ACCESS. 22"X36"
 MIN. AS PER SEC. 2309.6 SBC 1997.
 4-REVISE THE DESIGN CERTIFICATION FOR
 BUILDIONG CODE COMPLIANCE FORM.
 IF USING ASCE 7-95 AS DESIGN CRITERIA,
 THEN, THE WIND SPEED IS 145MPH.
 5-REVISE ENERGY CALCULATIONS. NEED TO
 COMPLETE FORM 600A. THIS IS A NEW
 SMALL BUILDING NOT AN ADDITION TO
 EXISTING BUILDING.
 6-PROVIDE PRODUCT APPROVALS FOR:
 A)SLIDING GLASS DOORS.
 B)SINGLE HUNG WINDOWS.
 C)ROOF SHINGLES.
 7-BRING DRAWINGS TO PALM BEACH COUNTY
 TO VERIFY IF IMPACT FEES ARE DUE.
 BRING STAMPED DRAWINGS AND RECEIPT.
  
  
 NOTES:
 -SEE PLANS FOR ADDITIONAL COMMENTS
 INCLUDING THOSE BY THE OTHER TRADES.
 -CONTRACTOR TO UPDATE INSURANCE AS REQ'D