2001-06-22 00:00:00 | CHECKLIST: |
| 1-PROVIDE NOTICE OF COMMENCEMENT. |
| 2-SIZE OF ATTIC ACCESS IS 22"X36" MIN. |
| SEC. 2309.6 SBC 1997. REVISE NOTE #7 |
| ON SHEET A-2. |
| 3-CLEARLY INDICATE SAFETY GLASS WHERE |
| REQUIRED. SEE PLANS FOR COMMENTS. |
| SEC. 2405.2 SBC 1997. |
| 4-PROVIDE COMPLETE DETAIL AND SPECS FOR |
| FRAMING OF ARCHED OPENINGS. SECTION |
| 104.2.2 CITY AMENDMENTS TO SBC 1997. |
| 5-OWES $275.92 FOR LOW VALUATION |
| DECLARED IN APPLICATION AND RADON FEES |
| 6-UPDATE ALL DRAWINGS AS REQUIRED. SEE |
| COMMENTS ON PLANS. |
| 7-PROVIDE COMPLETE INFORMATION FOR STORM |
| PANELS OR APPLY FOR A SEPARATE PERMIT. |
| 8-PROVIDE PRODUCT APPROVALS FOR: |
| A)DOUBLE ENTRY DOORS AS SHOWN ON PLANS. |
| B)FRENCH DOORS WITH SIDELITES & TRANSOM |
| ABOVE AS A SINGLE ASSEMBLY AS SHOWN ON |
| PLANS. |
| -FRENCH DOORS WITH TRANSOM ABOVE SINGLE |
| ASSEMBLY AS SHOWN ON PLANS. |
| C)MULLIONS FOR HORIZONTAL ASSEMBLIES. |
| PRODUCT APPROVAL SUBMITTED IS FOR |
| VERTICAL APPLICATIONS ONLY. |
| D)GARAGE SIDE DOOR. |
| |
| 9)UPDATE: |
| A)RINKER LETTER FOR MASONRY UNITS. |
| B)ENGINEERING SPECS FOR PRECAST LINTELS |
| SIGNED, SEALED AND DATED AS REQUIRED |
| BY CHAPTER 471 OF FLORIDA STATUTES. |
| |
| NOTES: |
| -PLEASE RETURN REVIEWED SETS AFTER |
| CORRECTIONS ARE DONE TO THE ORIGINAL |
| DRAWINGS IN ORDER TO EXPEDITE THE |
| REVIEW PROCESS. |
| -IF YOU HAVE ANY QUESTIONS PLEASE CALL |
| JULIO GOMEZ AT 659-8096 EXT. 8232. |