Notes |
Date |
Text |
2001-05-12 00:00:00 | APPROVED WITH PROVISO: | | | | 1-FLOOD ZONE AO. WILL NEED TO PROVIDE | | ELEVATION CERTIFICATE. | | | | 2-TOWNHOUSES ARE SEPARATED BY TWO HOUR | | FIRE RATED WALL. MODEL C HAS GLASS | | BLOCK AT ZERO LOT LINE. PROVIDE TWO | | HOUR FIRE RATED GLASS BLOCK OR CLOSE | | OPENING. SEC 704.4.2 SBC 1997. | | | | 3-PROVIDE PRODUCT APPROVAL FOR: | | -SLIDING GLASS DOORS. | | -2 HOUR FIRE RATED GLASS BLOCK. | | -PRECAST LINTEL(NOTE: CURRENT PRODUCT | | APPROVAL WILL EXPIRE ON 5-21-01) | | -WINDOW MULLIONS. | | | | 4-PROVIDE COMPLETE INSTALLATION SCHED. | | AND KEY PLAN FOR STORM PANELS. | | | | 5-REVISE NOTE #2 ON SHEET BP-1: MAX. | | CHANGE IN LEVEL IS 1/4" OR 1/2" MAX. | | IF BEVELED. FAIR HOUSING ACT PAGE 4.4. | | | | | | NOTE:THIS COMMENTS APPLY TO THE | | FOLLOWING PERMIT #S: 01040803, | | 01040806, 01040808 AND 01040810. |
|