Date |
Text |
2001-03-23 00:00:00 | CHECKLIST: |
| |
| 1-NOTICE OF COMMENCEMENT IS INCOMPLETE. |
| IT DOESN'T HAVE ANY INFORMATION |
| REGARDING THE GENERAL DESCRIPTION OF |
| IMPROVEMENTS. |
| 2-ARCHITECT TO REVISE THE DESIGN |
| CERTIFICATION FOR BUILDING CODE |
| COMPLIANCE FORM. SEE COMMENTS ON FORM. |
| AND, SIGN, SEAL AND DATE FORM AS |
| REQUIRED BY CHAPTER 481 FL. STATUTES. |
| 3-ARCHITECT TO SIGN, SEAL AND DATE THE |
| ENERGY CALCULATIONS AS REQUIRED BY |
| CHAPTER 471 FLORIDA STATUTES. |
| 4-CLARIFY HOW IS WATER RUNNING OUT OF |
| THE NEW ROOF. IS THERE ANY ROOF DRAIN. |
| SCUPPERS ARE SECONDARY DRAINAGE. |
| 5-PROVIDE COMPLETE INFORMATION FOR: |
| -CONNECTION OF STEEL COLUMN AT BASE. |
| -CONNECTION OF FLOOR JOISTS AND ROOF |
| RAFTERS AT BOTH ENDS. |
| -SPECIFY PLYWOOD SHEATHING FASTENING AS |
| PER SEC 2306 CITY AMENDMENTS TO SBC/97 |
| 6-SPECIFY THE DESIGN PRESSURES AT ALL |
| EXTERIOR OPENINGS. SEC. 1606 SBC 1997. |
| 7-PROVIDE TWO COPIES OF CURRENT SBCCI OR |
| DADE COUNTY APPROVAL FOR: |
| -FLAT ROOF SYSTEM. |
| -EXTERIOR DOORS AND WINDOWS (ONLY ONE |
| COPY WAS SUBMITTED). |
| 8-PROVIDE INSTALLATION DETAILS OF IRON |
| RAILING. SEC 1608.2 SBC 1997. |
| |
| |
| |