Date |
Text |
2001-03-02 00:00:00 | FAILED: |
| 1. ANY WORK PERFORMED IN CITY R.O.W AN |
| "APPLICATION FOR CONSTRUCTION WITHIN |
| PUBLIC RIGHT-OF-WAY" MUST BE SUBMITTED |
| TO CITY ENGINEER'S OFFICE.ALSO SUBMIT |
| SHOP DRAWING ON ALL MATERIALS TO PUBLIC |
| UTILITIES ENGINEERING SERVICES |
| DEPARTMENT 1000 45TH STREET WPB, FL |
| 33407 |
| 2. ALL DRIVEWAY APPROACHES MUST BE |
| CONSTRUCTED PER CITY OF WEST PALM BEACH |
| STANDARD.SEE ATTACHED |
| 3. INLET AT 2ND DRIVEWAY GOING NORTH |
| MAY REQUIRE ADJUSMENT(TOP ELEVATION), |
| PLEASE VERIFY. |
| 4. PLEASE RELOCATE THE EXISTING LIGHT |
| POLE AT DRIVEWAY ENTERING THE DROP-OFF |
| 5. PLEASE SHOW THE LOCATION OF CLEAN |
| OUTS FOR SANITARY SEWER LATERAL, ON |
| PROPERTY. |
| 6. PROVIDE CALCULATION FOR PERVIOUS AND |
| IMPERVIUS AREA CALCULATIONS ON A 8 1/2 X |
| 11 SHEET SIGNED AND SEALED BY THE DESIGN |
| ENGINEER DUE TO THE CHANGES.PLEASE |
| INCLUDE NAME OF THE PROPERTY, ADDRESS, |
| PROPERTY CONTROL NUMBER.THIS CAN BE |
| DONE WITH PERMIT APPLICATION. |
| 7. PLEASE SHOW THE NEW LOCATION OF |
| DUMPSTER.PLEASE NOTE THAT THE NEW |
| LOCATION SHOULD BE ACCESSIBLE AND SHOULD |
| BE CONSTRUCTED PER CITY OF WEST PALM |
| BEACH STANDARD. SEE ATTACHED STANDARD |
| 8. NOTE # 5 ON SHEET C-2 SHOWS S-III |
| ASPHALTIC CONCRETE, DETAILS SHOWS S-I, |
| PLEASE VERIFY |
| 9. DETAILS ON SHEET C-2 FOR PERFORATED |
| PIPE TRENCH SHOWS 24" COVER, IT SHOULD |
| 36" FOR UNDER TRAFFIC, PLEASE VERIFY. |
| 10. NOTE TO LANDSCAPE ARCHITECT, PLEASE |
| COMPLY WITH VISIBILITY TRIANGLE AT |
| CORNER OF DIXIE AND CRANEST WAY AND |
| PROVIDE 8' SIGHT LINE |
| 11. NOTE TO LANDSCAPE ARCHITECT, PLEASE |
| PROVIDE LANDSCAPING IN FRONT OF NEW |
| BACKFLOW PREVENTERS. |
| IF ANY QUSETION PLEASE CONTACT 659-8096 |
| EXT. 8492 |