Plan Review Notes
Plan Review Notes For Permit 01010736
Permit Number 01010736
Review Stop R
Sequence Number 3
Notes
Date Text
2001-11-15 00:00:00REVISION DENIED
  
 1) PROVIDE EMERGENCY ESCAPE AND EXIT
 OPENING IN SECOND FLOOR GUEST ROOM PER
 97 SBC SECTION 1005.4.1. THE MINIMUM
 NETCLEAR OPENING AREA SHALL BE 5.7
 SQ.FT., THE MINIMUM NET CLEAR OPENING
 HEIGHT OF 24" AND WIDTH OF 20" (SECT.
 1005.4.4) & SILL HEIGHT OF NOT MORE
 THAN 44"
 (SECT. 1005.4.3).
  
 2) INDICATE ACCESS TO ATTIC ACCESS TO
 COMPLY WITH 97 SBC SECT. 2309.6.
  
 3)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - STRUCTURAL WINDOW MULLIONS
 - STORM PANELS FOR FRENCH DOORS
  
 4) EXTERIOR EXITWAY STAIRS:
 - EXTERIOR STAIRS SHALL BE SEPARATED
 FROM THE INTERIOR OF THE BUILDING BY
 WALLS WITH A FIRE RESISTANCE RATING OF
 NOT LESS THAN ONE HOUR, WITH FIXED OR
 SELF-CLOSING OPENING PROTECTIVES AS
 REQUIRED FOR ENCLOSED STAIRS. THIS
 PROJECTION SHALL EXTEND VERTICALLY FROM
 THE GROUND TO A POINT 10 FT. ABOVE THE
 TOPMOST LANDING OR THE ROOF LINE,
 WHICH-EVER IS LOWER AND HORIZONTALLY 10
 FT.
 FROM EACH SIDE OF THE STAIRWAY.
 OPENINGSWITHIN THE 10 FT. HORIZONTAL
 EXTENSION
 OF THE PROTECTED WALLS BEYOND THE
 STAIRWAY SHALL BE EQUIPPED WITH FIXED
 3/4- HOUR ASSEMBLIES.
 (97 SBC SEC. 1006.2.4) THE NEW WINDOWS
 AND DOORS AT STAIRS MUST COMPLY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202
2001-10-30 00:00:00************BUILDING PROVISO************
  
 1) PROVIDE MANUFACTURES SPECIFICATIONS,
 UL LISTING INFORMATION, STRUCTURAL
 DRAWINGS AND ELEVATION DRAWINGS FOR
 VENTLESS FIRE BOX PRIOR TO INSTALLATION.
 INSTALLATION MUST COMPLY WITH CHAPTER 9
 OF THE 97 STANDARD MECHICAL CODE.
 A SEPARATE GAS PERMIT WILL BE REQUIRED
 IF USING A GAS APPLIANCE IN FIRE BOX.
  
 2) PROVIDE PRODUCT APPROVALS FOR DOUBLE
 INSWING ENTRY DOORS WITH SIDELITES,
 PRIOR TO INSTALLATION. UNIT MUST COMPLY
 WITH LARGE MISSLE IMPACT PROTECTION
 REQUIREMENTS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202
  
 REVISION WAS RESUBMITTED ON 11-8-01 FOR
 PLBG. AND ELEC. THE ITEMS REQUESTED IN
 ABOVE PROVISO WERE ADDRESSED.
 RM 11-15-01