2001-02-15 00:00:00 | SECOND CHECKLIST: |
| 1-IMPACT FEES ARE STILL NOT PAID. PAY |
| IMPACT FEES TO PALM BEACH COUNTY AND |
| BRING STAMPED DRAWINGS AND RECEIPT. |
| 2-STORM PANELS INFORMATION IS STILL |
| INCOMPLETE: |
| -NEED KEY PLAN THAT MATCHES MODEL. |
| -STORM PANEL DWG #01-246 CAN'T BE USED |
| AS A REFERENCE BECAUSE IT IS NOT PART |
| OF THE DRAWINGS APPROVED IN THE SBCCI |
| EVALUATION REPORT. |
| -SEE LIMITATIONS ON SHEET 3 OF 3 OF |
| SBCCI REPORT REGARDING THE USE OF TRU- |
| FAST TAP GRIP ANCHORS. CHECK THE MIN. |
| COMPRESSIVE STRENGTH OF CONCRETE |
| MASONRY UNITS. |
| -CLEARLY INDICATE ON ANCHOR SCHEDULE |
| THE SPECIFIC MOUNTING CONDITIONS AND |
| ANCHOR TYPE AND SPACING TO BE USED |
| ACCORDING TO THE DESIGN PRESSURES, |
| MIN. EDGE DISTANCE, MAX. PANEL SPAN, |
| CONNECTION TYPE AND STRUCTURE TO BE |
| ATTACHED TO (NOTE: THIS IS CONCRETE |
| BLOCK CONSTRUCTION, NOT CONCRETE). |
| -ALL THIS INFORMATION MAY BE SUBMITTED |
| UNDER A SEPARATE PERMIT. |
| 3-PROVIDE CURRENT SBCCI OR DADE COUNTY |
| PRODUCT APPROVAL FOR: |
| -GARAGE SIDE DOOR. SEE SIZE SPECIFIED |
| ON PLANS. |
| -WINDOW MULLIONS, SINGLE HUNG WINDOWS, |
| RECTANGULAR WINDOWS & ARCHED WINDOWS. |
| NORANDEX PRODUCT APPROVAL IS NOT |
| ACCEPTABLE UNLESS IT IS SIGNED, SEALED |
| AND DATED BY THE ENGINEER OF RECORD |
| FOR THIS SPECIFIC LOCATION. |
| 4-PROVIDE SOIL TEST REPORT AS PER SEC. |
| 1804.2.7 AND TABLE 1804.2.7.3 OF CITY |
| AMENDMENTS TO SBC 1997. |
| NOTE: THIS REPORT WAS NEVER SUBMITTED |
| TO THE CITY FOR REVIEW. |
| -ALSO, CLARIFY WHY DENSITY TEST |
| SUBMITTED IS DONE WITH THE NAME OF |
| ANOTHER BUILDER. |