Notes |
Date |
Text |
2001-01-08 00:00:00 | 1)SHTS.A-1.1,1.2-DOORS CANNOT SWING INTO | | THE CLEAR FLOOR SPACE REQD.FOR THE | | LAVATORIES.FACBC SEC.4.22.2. | | | | 2)SHOW THE REQD.WHEELCHAIR TURNING SPACE | | IN EACH TOILET ROOM.COMPLY W/FACBC SEC. | | 4.2.3. | | | | 3)EACH COMMON AND PUBLIC USE TOILET | | ROOM SHALL BE FULLY ACCESSIBLE PER | | FACBC SEC.4.1.3.(11). | | | | 4)SHT.A-1.0-NOTE #F-GRAB BAR BEHIND THE | | WATER CLOSET SHALL BE 36"MIN.PER FACBC | | 4.16.4. | | | | 5)SUBMIT MANUF.SHEETS FOR TUBAL GAS | | MACHINE,SUCTION MACHINE AND STERILIZ- | | ATION MACHINE. | | | | CALL IF YOU HAVE QUESTIONS. | | 561-659-8096,EXT.8377. | | | | TIMOTHY LARGE | | PLUMBING PLANS EXAMINER. |
|