Date |
Text |
2001-01-08 00:00:00 | APPROVED WITH PROVISO: |
| 1-PROVIDE SOIL TEST REPORT AS PER SECT'N |
| 1804.2.7.2 AND TABLE 1804.2.7.3 OF |
| CITY AMENDMENTS TO SBC 1997. |
| 2-PROVIDE COMPLETE STORM PANELS INFO. |
| UNDER A SEPARATE PERMIT. |
| 3-PROVIDE PRODUCT APPROVAL FOR: |
| -INSWING FRENCH DOOR WITH SIDELITES. |
| -BBQ UL LISTING AND SPECIFICATIONS. |
| -OUTSWING FRENCH DOORS. |
| 4-USE SITE SPECIFIC PRODUCT APPROVAL |
| FORM ATTACHED FOR INSWING ENTRY DOOR. |
| |
| -THIS FORM TO BE SIGNED, SEALED & DATED |
| BY THE MANUFACTURER'S ENGINEER AND BY |
| THE ENGINEER OF RECORD. |
| -PLEASE AVOID UNNECESSARY RETURNS. MAKE |
| SURE FORM IS FILLED COMPLETELY WITH |
| ALL THE SPECIFICATIONS AND THE |
| ENGINEERS NAMES, LICENSE NUMBERS AND |
| ADDRESSES ARE CLEARLY INCLUDED. |
| -FILL IN THE JOB SPECIFIC ADDRESS. |
| 5-PROVIDE CERTIFICAT'N FROM MANUFACTURER |
| STATING THAT CONCRETE BLOCK EQUIVALENT |
| THICKNESS WILL PROVIDE TWO HOUR FIRE |
| RATING ACCORDING TO ASTM C 140. |
| SECTION 709.3 SBC 1997. |
| 6-REVISE DOOR BUCK DETAIL. BUCK SIZE IS |
| 2X4 AND ANCHOR SPECIFIED IS 1 1/2" |
| LONG. |
| 7-GARAGE DOOR APPROVED DRAWINGS ARE NOT |
| LEGIBLE. PLEASE RESUBMIT. |
| 8-FLOOD ZONE "AO". PROVIDE ELEVATION |
| CERTIFICATE. |
| |
| NOTES: |
| -IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| JULIO GOMEZ AT 659-8096 EXT. 8232. |