2001-01-08 00:00:00****************DENIED******************
  
 1)IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY,PLANS STAMPED BY THEM AND RECEIPT
 SUBMITTED TO CITY OF WPB CONSTRUCTION
 SERVICES DEPT. BEFORE A PERMIT TO
 CONSTRUCT WILL BE ISSUED.
  
 2)STRUCTURE IS LOCATED IN AN "AO" FLOOD
 ZONE. PLEASE PROVIDE ELEVATION
 CERTIFICATE WHEN PROJECT IS COMPLETE PER
 FEMA REQUIREMENTS.
  
 3)PROVIDE SOIL COMPACTION TEST AT FIRST
 INSPECTION.
  
 4)PROVIDE ENGINEERING OR LETTER FROM
 MANUFACTURER CERTIFYING THE APPLICATION
 OF JOIST HANGER EHUH 210 ON MASONRY AND
 THE SIZE,TYPE AND NUMBER OF FASTENERS
 REQUIRED.
  
 5)PLEASE PROVIDE ADDITIONAL DATA ON 2 HR
 FIRE RATED BLOCK THAT WILL BE USED ON
 THIS PROJECT.
  
 6)DETAIL #6 ON SHEET 8 IS CROSSED OUT,
 HOWEVER IT IS REFERENCED ON SHEET 7.
 PLEASE CLARIFY AND SPECIFY CONNECTOR TO
 BE USED FOR GIRDER TRUSSES ON PORCHES.
  
 7)DETAIL 2A ON SHEET 8 IS CROSSED OUT,
 YET IT IS REFERENCED ON SHEET 7.
  
 8)PLEASE USE CITY OF WPB PRODUCT APPROV-
 AL SUBMITTAL FORM WHEN SUBMITTING SITE
 SPECIFIC ENGINEERING. PROVIDE SPECIFIC
 JOB/SITE LOCATION (ADDRESS,LOT#)ON FORM.
 ALSO ENGINEER/ARCHITECT IS REQUIRED TO
 PROVIDE LEDGIBLE NAME,ADDRESS AND
 REGISTRATION NUMBER ON FORM. PER FL STAT
 UTES.
  
 8)THE WIND LOADS GIVEN ON SHEET 5 OF
 PLANS FOR THE SLIDING GLASS DOORS EXCEED
 THE DESIGN LOAD CAPACITIES OF THE DOORS
 ON THE PRODUCT SUBMITTAL FORM. PLEASE
 RECHECK THE CALCULATIONS.