2001-01-08 00:00:00 | CHECKLIST: |
| 1-PAY IMPACT FEES TO PALM BEACH COUNTY |
| AND BRING STAMPED DRAWINGS AND RECEIPT |
| 2-LEFT SIDE ELEVATION EXCEEDS THE MAX. |
| PERCENTAGE OF OPENINGS ALLOWED BY |
| TABLE 600 OF SBC 1997. |
| 3-PROVIDE ONE HOUR FIRE RATED ASSEMBLY |
| AT ZERO LOT LINE. INCLUDING AREA AT |
| TRANSITION FROM CONCRETE BLOCK TO WOOD |
| FRAMING. THE FIRE RESISTANCE FOR |
| EXTERIOR WALLS AT ZERO LOT LINE SHALL |
| BE UPON BOTH INTERIOR & EXTERIOR FIRE |
| EXPOSURE. TABLE 600, NOTE I. SBC/97 |
| ALSO, SEE SECTION 709.6.2.2 SBC 1997. |
| 4-SURVEY TO BE SIGNED, SEALED AND DATED |
| CHAPTER 471 FLORIDA STATUTES. |
| 5-PROVIDE SOIL TEST REPORT PERFORMED AS |
| PER SECTION 1804.2.7.2 OF CITY |
| AMENDMENTS. |
| 6-ARCHITECTURAL DRAWINGS NEED ORIGINAL |
| SIGNATURE. CHAPTER 481 FL. STATUTES. |
| 7-GENERAL NOTES SHEET TO BE UPDATE AS |
| REQUIRED. CITY OF WEST PALM BEACH HAS |
| ADOPTED THE SBC 1997 AND FLORIDA |
| ENERGY EFFICIENCY CODE FOR BUILDING |
| CONSTRUCTION, 1997 EDITION. REVIEW ALL |
| DIVISIONS (EG: CONCRETE, MASONRY, ETC) |
| AND REFERENCE THE APPROPRIATE STANDARD |
| ACCORDING TO SBC AND THE ENERGY CODE |
| RESPECTIVELY. |
| 8-COMPLETELY SPECIFY CEILING CONSTRUCT'N |
| AT ENTRY AND REAR PORCHES. INCLUDING |
| FASTENERS TYPE AND SPACING. SECTION |
| 2504.2 SBC 1997. |
| 9-ATTIC ACCESS IN MASTER BEDROOM CLOSET |
| TO BE 22"X36" MIN. SEC. 2309.6 SBC/97. |
| SPECIFY SIZE FOR SECOND FLOOR ROOF. |
| 10-PROVIDE DRAFSTOPPING AT SECOND FLOOR |
| FRAMING PLAN. SPECIFY LOCATION AND |
| TYPE OF MATERIAL. SEC. 2305.2.2 SBC/97 |
| 11-REVISE THE DESIGN CERTIFICATION FOR |
| BUILDING CODE COMPLIANCE FORM: |
| -IMPORTANCE FACTOR IS INCORRECT. SEE |
| TABLE 1606 SBC 1997. |
| -BASIC VELOCITY PRESSURE IS INCORRECT. |
| SEE TABLE 1606.2A SBC 1997. |
| -FORM IS NOT LEGIBLE. |
| 12-PROVIDE PRODUCT APPROVAL FOR: |
| -ENTRY DOUBLE DOORS. |
| -HORIZONTAL SLIDERS (MISSING DRAWINGS). |
| -SLIDING GLASS DOORS (LEGIBLE DRAWINGS) |
| -ARCHED WINDOWS (LEGIBLE DRAWINGS). |
| -WINDOW MULLIONS (NOTE: TO BE USED WITH |
| WINDOWS W/ CURRENT PRODUCT APPROVAL). |
| -ONE HOUR FIRE RATED GLASS BLOCK. |
| 13-PROVIDE BUCK DETAILS SHOWING 2X SIZE |
| OF BUCK. SEE PRODUCT APPROVAL FOR |
| FIXED AND ARCHED WINDOWS. |
| 14-SEE PLANS FOR ADDITIONAL COMMENTS. |
| INCLUDING THOSE BY THE OTHER TRADES. |
| 15-STORM PANELS: |
| -SPECIFY ANCHORS FOR WOOD FRAMING. |
| -WHAT'S AN ANCHOR D?. |
| -HIGHLIGHT SPECIFIC MOUNTING CONDITIONS |
| ON PAGE 2 OF 5. |
| |
| NOTES: |
| |
| 1-CONTRACTOR NEEDS TO UPDATE LICENSE. |
| PLEASE CONTACT MICHELLE MCLEAN AT |
| 659-8096 EXT. 8242 OR ANGIE NEIL AT |
| EXT. 8289 FOR INFORMATION REQUIRED. |
| 2-VALUE DECLARED ON THE APPLICATION WAS |
| TOO LOW. THIS VALUE WILL BE ADJUSTED |
| AND ADDITIONAL FEES WILL BE DUE, |
| INCLUDING RADON FEES. |
| 3-PLEASE RETURN REVIEWED SET OF DRAWINGS |
| IN ORDER TO EXPEDITE THE REVIEW |
| PROCESS. |