Date |
Text |
2001-01-08 00:00:00 | DENIED |
| |
| 1)IMPACT FEES MUST BE PAID TO PALM BEACH |
| COUNTY, PLANS STAMPED BY THEM AND COPY |
| OF RECIEPT SUBMITTED TO CITY OF WPB |
| BUILDING DEPT. BEFORE A PERMIT CAN BE |
| ISSUED. |
| |
| 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE |
| OR SBCCI PRODUCT APPROVALS FOR EXTERIOR |
| WINDOW SHOWN ON PLANS. |
| |
| 3)MISSLE IMPACT PROTECTION IS REQUIRED |
| FOR ALL EXTERIOR GLAZING. CITY AMENDMENT |
| TO 97 SBC 1606.4. |
| |
| 4)PROVIDE 2 CURRENT COPIES OF METRO-DADE |
| OR SBCCI PRODUCT APPROVALS INDICATING |
| SPECIFIC ANCHORS TO BE USED FOR STORM |
| PANELS. |
| |
| 5)SAFETY GLASS IS REQUIRED IN BATHROOM |
| WINDOW WHERE BOTTOM EDGE OF GLAZING IS |
| LESS THAN 60" ABOVE DRAIN INLET. 97 SBC |
| 2405.2 |
| |
| 6)PROVIDE R-11 INSULATION IN FLOOR PER |
| 1997 FLORIDA ENERGY CODE. |
| |
| 7)R-19 BAT INSULATION WILL NOT FIT IN A |
| 2X4 WALL AS INDICATED ON PLANS.CLARIFY. |
| |
| 8)PLANS INDICATE U-BLOCK ON TOP OF STEM |
| WALL. INDICATE TYPE OF STEEL REINFORCE- |
| MENT TO BE USED. |
| |
| 9)PROVIDE FIRE STOPS AT CEILING IN |
| BALLOON FRAMED EXTERIOR WALL.97 SBC 2305 |
| |
| 10)PROVIDE ACCESS TO ATTIC.97 SBC 2309.6 |
| |
| 11)PROVIDE CRAWL SPACE VENTILATION PER |
| 97 SBC 1804.6.2.1 |
| |
| 12)SPECIFY CRAWL SPACE ACCESS OPENING |
| SIZE PER 97 SBC 1804.6.2.2 |
| |
| 13)CLARIFY CONNECTION OF FLOOR JOISTS TO |
| P.T. SILL PLATE. |
| |
| 14)SPECIFY TYPE OF CONNECTORS USED TO |
| ANCHOR NEW RAFTERS TO LEDGER ON EXISTING |
| ROOF AND RAFTER TO RIDGE CONNECTIONS. |
| |
| 15)CLARIFY ATTACHMENT OF GABLE WALL TO |
| ROOF CONNECTIONS. |
| |
| 16)CLARIFY 12" MAXIMUM SPACING OF NAILS |
| AT 2X6 LEDGER ON EXISTING ROOF. SHOULD |
| IT BE NAILED AT EVERY RAFTER OR TRUSS. |