Plan Review Notes
Plan Review Notes For Permit 00071214
Permit Number 00071214
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00DENIED
  
 1)IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY, PLANS STAMPED BY THEM AND COPY
 OF RECIEPT SUBMITTED TO CITY OF WPB
 BUILDING DEPT. BEFORE A PERMIT CAN BE
 ISSUED.
  
 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR EXTERIOR
 WINDOW SHOWN ON PLANS.
  
 3)MISSLE IMPACT PROTECTION IS REQUIRED
 FOR ALL EXTERIOR GLAZING. CITY AMENDMENT
 TO 97 SBC 1606.4.
  
 4)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS INDICATING
 SPECIFIC ANCHORS TO BE USED FOR STORM
 PANELS.
  
 5)SAFETY GLASS IS REQUIRED IN BATHROOM
 WINDOW WHERE BOTTOM EDGE OF GLAZING IS
 LESS THAN 60" ABOVE DRAIN INLET. 97 SBC
 2405.2
  
 6)PROVIDE R-11 INSULATION IN FLOOR PER
 1997 FLORIDA ENERGY CODE.
  
 7)R-19 BAT INSULATION WILL NOT FIT IN A
 2X4 WALL AS INDICATED ON PLANS.CLARIFY.
  
 8)PLANS INDICATE U-BLOCK ON TOP OF STEM
 WALL. INDICATE TYPE OF STEEL REINFORCE-
 MENT TO BE USED.
  
 9)PROVIDE FIRE STOPS AT CEILING IN
 BALLOON FRAMED EXTERIOR WALL.97 SBC 2305
  
 10)PROVIDE ACCESS TO ATTIC.97 SBC 2309.6
  
 11)PROVIDE CRAWL SPACE VENTILATION PER
 97 SBC 1804.6.2.1
  
 12)SPECIFY CRAWL SPACE ACCESS OPENING
 SIZE PER 97 SBC 1804.6.2.2
  
 13)CLARIFY CONNECTION OF FLOOR JOISTS TO
 P.T. SILL PLATE.
  
 14)SPECIFY TYPE OF CONNECTORS USED TO
 ANCHOR NEW RAFTERS TO LEDGER ON EXISTING
 ROOF AND RAFTER TO RIDGE CONNECTIONS.
  
 15)CLARIFY ATTACHMENT OF GABLE WALL TO
 ROOF CONNECTIONS.
  
 16)CLARIFY 12" MAXIMUM SPACING OF NAILS
 AT 2X6 LEDGER ON EXISTING ROOF. SHOULD
 IT BE NAILED AT EVERY RAFTER OR TRUSS.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved