Plan Review Notes For Permit 00071187 |
Permit Number |
00071187 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2001-01-08 00:00:00 | SUBMIT SQ.FOOTAGE OF SPACE TO ENSURE | | COMPLIANCE W/TABLE 407 OF SPC. | | | | 2)A DRINKING FOUNTAIN IS REQD.PER SPC | | TABLE 407.DRINKING FOUNTAIN SHALL COMPLY | | W/FACBC SEC.4.1.3.(10)(A),4.15. | | | | 3)HANDICAP DRESSING ROOM SHALL COMPLY W/ | | FACBC 4.35.BENCH SHALL BE LOCATED ALONG | | WALL WITH THE LONGER DIMENSION. | | | | 4)HANDICAP TOILET ROOM SHALL BE | | INDELIBLY POSTED FOR THE INTENDED USE | | PER FACBC SEC.4.1.2(7),4.1.3(16)(A). | | | | 5)ACCESSIBLE TOILET ROOMS SHALL BE | | LOCATED ON AN ACCESSIBLE ROUTE. | | ACCESSIBLE ROUTE SHALL BE CLEARLY | | DEFINED ON THE PLANS.FACBC SECS.4.1.3 | | (11),4.2.1,4.3.1,4.3.2(3),4.3.3. | | | | 6)TOILET FACILITIES SHALL BE AVAILABLE | | TO PATRONS WITHOUT RESTRICTION DURING | | NORMAL OPERATING HOURS.SPC SEC.407.2.2. | | | | 7)FLUSH CONTROLS FOR WATER CLOSET SHALL | | BE LOCATED ON THE WIDE SIDE OF THE | | TOILET.FACBC SEC.4.16.5. |
|