Plan Review Notes
Plan Review Notes For Permit 00071044
Permit Number 00071044
Review Stop P
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00PLUMBING PLAN REVIEW REF SPC 94
 (1A) SHT A-3,1 DRINKING FOUNTAIN
 REQUIRED TAB 407, TO COMPLY W/FACBC
 SEC 4.1.3 (10) (A) PROVISIONS SHALL BE
 MADE FOR PEOPLE WHO HAVE TROUBLE BENDING
 OR STOOPING.
 (B)ACCESS TO PUBLIC REST ROOMS THRU A
 STORAGE AREA,TO COMPLY W/ FACBC 4.1.2(7)
 4.1.3(16) SINAGE, REST RM'S TO BE
 LOCATED ON AN ACCESSIBLE ROUTE FACBC
 SEC4.1.3.(11),4.2.1,4.3.1,4.3.2(3),
 4.3.3 ACCESSIBLE ROUTE SHALL BE CLEARLY
 DEFINEED ON PLANS.
 SPC SEC 407.2.2 TOILET FACILITIES SHALL
 BE AVILABLE TO PATRONS WITHOUT
 RESTRICITION DURING NORMAL OPERATING
 HOURS.
 (B) 1 DRINKING FOUNTAIN REQUIRED TAB 407
 TO COMPLY W/FACBC 4.1.3(10)(A),
 PROVISIONS SHALL BE MADE FOR PEOPLE WHO
 HAVE TROUBLE BENDING OR STOOPING.
 (C) H/C FITTING ROOM TO COMPLY W/FACBC
 4.35.4 FIXED BENCH ALONG THE LONGER
 DIMENSION, THE BENCH SHALL BE 24"X48"X
 17" TO 19" AFF.
 (D)CASH WRAP COUNTRER,TO COMPLY W/FACBC
 7.2(2)(I) A PORTION OF THEN COUNTER TO
 BE 36"IN LGTH, WITH A MAX HGTH OF 36"AFF
 END OF COMMENTS