Plan Review Notes For Permit 00070815 |
Permit Number |
00070815 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2001-01-08 00:00:00 | 1)LAVATORIES IN RESTROOMS INFRINGE ON | | CLEAR FLOOR SPACE FOR WATER CLOSET. | | COMPLY W/FACBC SEC.4.17.3.FIGURE 30(A). | | | | 2)PLANS SHALL BE ROUTED TO DEPT.OF | | BUSINESS REGULATION FOR REVIEW AND | | APPROVAL.COUNTYWIDE AMENDMENTS TO SPC | | SEC.101.4.7. | | | | 3)CLEANOUTS IN GREASY WASTE AND SANITARY | | SHALL COMPLY W/ SPC SEC.710.2. | | | | 4)UNION REQD.DOWNSTREAM OF MANUAL | | CONTROL VALVE FOR SYSTEM PER NFPA 54, | | SEC.5.5.4. | | | | 5)SANITARY SYSTEM FOR TOILET ROOMS SHALL | | COMPLY W/SPC SEC.914.1 FOR CIRCUIT AND | | LOOP SYSTEM. | | | | 6)WATER HEATER RELIEF LINE SHALL NOT | | DISCHARGE TO THE GREASE SYSTEM PER | | COUNTYWIDE AMENDMENTS TO SPC SEC.507.8.4 | | | | 7)INDICATE TYPE OF MATERIAL USED FOR THE | | GAS SYSTEM.RECALCULATE YOUR BTU LOAD ON | | THE SYSTEM. | | | | 8)GAS SYSTEM IS NOT PROPERLY SIZED PER | | SGC SEC.305.4. | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | ANY COMMENTS. | | | | TIMOTHY LARGE | | PLUMBING PLANS EXAMINER. |
|