2001-01-08 00:00:00 | APPROVED WITH PROVISO: |
| 1-FLOOD ZONE "AO". NEED TO PROVIDE AN |
| ELEVATION CERTIFICATE. |
| 2-ENERGY CALCULATIONS: |
| -REVISE CEILING AREA AS REQUIRED PER |
| SECTION 604.1.A.1 OF FLORIDA ENERGY |
| EFFICIENCY CODE FOR BUILDING |
| CONSTRUCTION, 1997 EDITION. |
| 3-SEE COMMENTS ON PLANS REVISE/UPDATE |
| AS REQUIRED FOR FUTURE SUBMITTALS. |
| 4-COMPLETELY SPECIFY CEILING CONSTRUCT'N |
| AT FRONT AND BACK PORCHES. INCLUDING |
| FASTENERS TYPE AND SPACING. SECTION |
| 2504 SBC 1997. |
| 5-PROVIDE COMPLETE AND LEGIBLE PRODUCT |
| APPROVALS FOR: GLASS BLOCK, SLIDING |
| GLASS DOORS, ENTRY DOOR AND CIRCLE TOP |
| WINDOWS. |
| 6-STORM PANELS: |
| -PROVIDE INSTALLATION SCHEDULE. PLEASE, |
| USE CITY SAMPLE AND FILL IN ALL THE |
| INFORMATION AS SHOWN ON SAMPLE TO |
| ASSURE PROPER INSTALLATION. |
| -MARK ANCHOR INSTALLATION SCHEDULE |
| ACCORDING TO THE MEAN ROOF HEIGHT, |
| DESIGN PRESSURES, EDGE DISTANCE, STORM |
| SPAN, CONNECTION TYPE AND STRUCTURE TO |
| BE ATTACHED TO. |
| NOTE: BE AWARE THAT WINDOW SILLS ARE |
| BE AWARE THAT WINDOW SILLS ARE MASONRY |
| UNITS. THEREFORE, STRUCTURE TO RECEIVE |
| STORM PANELS IS CONCRETE BLOCK NOT |
| 3,000 PSI CONCRETE. |
| 7-PROVIDE SOIL TEST REPORT AS PER SEC. |
| 1804.2.7 OF CITY AMENDMENTS. |
| 8-FOR FUTURE SUBMITTALS, PLEASE CLEARLY |
| INDICATE THE STRUCTURAL DETAILS THAT |
| ARE RELATED TO THE SPECIFIC HOUSE AND |
| THE OPTION THAT IS GOING TO BE BUILT |
| IN ORDER TO EXPEDITE THE REVIEW |
| PROCESS. |