Notes
Date Text
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO". PROVIDE ELEVATION
 CERTIFICATE.
 2-PROVIDE A COMPLETE WALL SECTION AT TWO
 STORY CBS WALL. INCLUDE DETAIL/SPECS
 OF HOW IS SECOND FLOOR FRAMING
 ANCHORED TO THIS WALL. SECTION 104.2.2
 CITY AMENDMENTS TO SBC 1997.
 3-PROVIDE SAFETY GLASS AT BEDROOM #4.
 SECTION 2405.2 SBC 1997 (NOT 1999 ED.)
 4-PROVIDE COMPLETE STAIR SECTION/DETAILS
 AND SPECIFICATIONS. SECTION 1007 SBC.
 INCLUDE FIREBLOCKING, RAILINGS, ETC.
 5-SPECIFY DRAFSTOPPING TYPE AND LOCATION
 AT SECOND FLOOR FRAMING PLAN. SECTION
 2305.2.2 SBC 1997.
 6-PROVIDE SPECIFICATIONS/DETAILS FOR
 CEILING CONSTRUCTION AT ENTRY AND REAR
 PORCHES.
 SPECIFY ANCHOR TYPES AND SPACING.
 SECTION 2504 SBC 1997.
 7-PROVIDE PRODUCT APPROVAL FOR WINDOW
 MULLIONS, OVAL WINDOW AND SLIDING
 GLASS DOORS.
 -TWO HOUR CONCRETE BLOCK: PROVIDE
 CERTIFICATION FROM MANUFACTURER'S
 ENGINEER STATING THAT CONCRETE BLOCK
 EQUIVALENT THICKNESS COMPLIES WITH
 ASTM C140 FOR FIRE RESISTANCE.
 SECTION 709.3 SBC 1997.
 8-SEE COMMENTS ON PLANS AND REVISE/
 UPDATE DRAWINGS AS REQUIRED.
 INCLUDING COMMENTS BY OTHER TRADES.
 SEE LAST THREE PAGES OF BLUEPRINTS FOR
 THEIR COMMENTS.